Multiplexed hydraulic valve actuation using ionic liquid filled soft channels and Braille displays

被引:53
作者
Gu, Wei [1 ]
Chen, Hao
Tung, Yi-Chung
Meiners, Jens-Christian
Takayama, Shuichi
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Phys, Div Biophys Res, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Macromol Sci & Engn, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
D O I
10.1063/1.2431771
中图分类号
O59 [应用物理学];
学科分类号
摘要
Pneumatic actuation with multilayer soft lithography enables operation of up to thousands of valves in parallel using far fewer control lines. However, it is dependent on macroscopic switches and external pressure sources that require interconnects and limit portability. The authors present a more portable and multiplexed valve actuation strategy that uses a grid of mechanically actuated Braille pins to hydraulically, rather than pneumatically, deform elastic actuation channels that act as valves. Experimental and theoretical analyses show that the key to reliable operation of the hydraulic system is the use of nonvolatile ionic liquids as the hydraulic fluid. (c) 2007 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 17 条
[1]   Layered fluid model and flow simulation for microchannels using electrical networks [J].
Aumeerally, M ;
Sitte, R .
SIMULATION MODELLING PRACTICE AND THEORY, 2006, 14 (01) :82-94
[2]   Functional hydrogel structures for autonomous flow control inside microfluidic channels [J].
Beebe, DJ ;
Moore, JS ;
Bauer, JM ;
Yu, Q ;
Liu, RH ;
Devadoss, C ;
Jo, BH .
NATURE, 2000, 404 (6778) :588-+
[3]   Modeling micropumps with electrical equivalent networks [J].
Bourouina, T ;
Grandchamp, JP .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1996, 6 (04) :398-404
[4]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[5]   Handheld recirculation system and customized media for microfluidic cell culture [J].
Futai, N ;
Gu, W ;
Song, JW ;
Takayama, S .
LAB ON A CHIP, 2006, 6 (01) :149-154
[6]   Computerized microfluidic cell culture using elastomeric channels and Braille displays [J].
Gu, W ;
Zhu, XY ;
Futai, N ;
Cho, BS ;
Takayama, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (45) :15861-15866
[7]   A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion [J].
Hansen, CL ;
Skordalakes, E ;
Berger, JM ;
Quake, SR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (26) :16531-16536
[8]   Microfluidic devices with tunable microtopographies [J].
Hsu, CH ;
Folch, A .
APPLIED PHYSICS LETTERS, 2005, 86 (02) :023508-1
[9]   A miniaturized, parallel, serially diluted immunoassay for analyzing multiple antigens [J].
Jiang, XY ;
Ng, JMK ;
Stroock, AD ;
Dertinger, SKW ;
Whitesides, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (18) :5294-5295
[10]  
KOVACS GTA, 1998, MICROMACHINED TRANSD, P779