Noninvasive in vivo magnetic resonance imaging of experimental coronary artery lesions in a porcine model

被引:73
作者
Worthley, SG
Helft, G
Fuster, V
Fayad, ZA
Rodriguez, OJ
Zaman, AG
Fallon, JT
Badimon, JJ
机构
[1] Mt Sinai Med Ctr, Zena & Michael A Wiener Cardiovasc Inst, Cardiovasc Biol Res Lab, New York, NY 10029 USA
[2] Mt Sinai Med Ctr, Dept Radiol, New York, NY 10029 USA
[3] Mt Sinai Med Ctr, Dept Pathol, New York, NY 10029 USA
关键词
magnetic resonance imaging; arteries;
D O I
10.1161/01.CIR.101.25.2956
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The ability to characterize and quantify coronary artery atherosclerotic lesions accurately, reproducibly, and noninvasively may allow the stratification of risk for future acute coronary syndromes and help direct therapeutic management. MRI has been shown to accurately characterize and quantify atherosclerosis; however, because of the combination of cardiac and respiratory motion artifacts, nonlinear course, and relatively small size of the coronary arteries, these techniques have not been able to be translated to the coronary system in vivo. Methods and Results-Coronary lesions were induced in Yorkshire albino swine (n=6) with balloon angioplasty, and 4 weeks later MRI of the coronary artery lesions was performed. High-resolution in vivo images of the coronary artery wall and lesions were obtained with a double-inversion-recovery fast-spin-echo sequence in a 1.5-T MR system. There was good agreement between measurements of vessel wall thickness and area from MR images of the coronary arteries and the matched histopathology sections (n=43). The mean difference (MRI minus histopathology +/- SD) for mean wall thickness was 0.26+/-0.18 mm, and for vessel wall area, 5.65+/-3.51 mm(2). MRI was also able to visualize intralesion hematoma (sensitivity 82%, specificity 84%). Conclusions-Using a clinical MR system, we were able to image coronary artery lesions in vivo in an experimental porcine model. Further studies are needed to assess the ability of MRI to characterize coronary atherosclerotic in vivo.
引用
收藏
页码:2956 / 2961
页数:6
相关论文
共 22 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]   Cholesterol lowering and coronary artery disease: mechanisms of risk reduction [J].
Archbold, RA ;
Timmis, AD .
HEART, 1998, 80 (06) :543-547
[3]   Carotid plaque characterization by duplex scanning - Observer error may undermine current clinical trials [J].
Arnold, JAC ;
Modaresi, KB ;
Thomas, N ;
Taylor, PR ;
Padayachee, TS .
STROKE, 1999, 30 (01) :61-65
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Coronary risk factors and plaque morphology in men with coronary disease who died suddenly [J].
Burke, AP ;
Farb, A ;
Malcom, GT ;
Liang, YH ;
Smialek, J ;
Virmani, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (18) :1276-1282
[6]   Noninvasive detection of atherosclerosis [J].
Celermajer, DS .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :2014-2015
[7]   Stability and instability: Two faces of coronary atherosclerosis - The Paul Dudley White Lecture 1995 [J].
Davies, MJ .
CIRCULATION, 1996, 94 (08) :2013-2020
[8]  
DAVIES MJ, 1985, BRIT HEART J, V53, P363
[9]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[10]   Noninvasive in vivo high-resolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice [J].
Fayad, ZA ;
Fallon, JT ;
Shinnar, M ;
Wehrli, S ;
Dansky, HM ;
Poon, M ;
Badimon, JJ ;
Charlton, SA ;
Fisher, EA ;
Breslow, JL ;
Fuster, V .
CIRCULATION, 1998, 98 (15) :1541-1547