Review of biomedical optical imaging-a powerful, non-invasive, non-ionizing technology for improving in vivo diagnosis

被引:134
作者
Balas, Costas [1 ]
机构
[1] Tech Univ Crete Chania, Dept Elect & Comp Engn, Iraklion, Greece
关键词
biomedical optical imaging; spectroscopy; optical tomography; spectral imaging; optical coherence tomography; confocal imaging; endoscopy; microendoscopy; dynamic spectral imaging; cervix; neoplasia; cancer; COHERENCE TOMOGRAPHY; BREAST-CANCER; ACETIC-ACID; HIGH-SPEED; FLUORESCENCE SPECTROSCOPY; DIFFUSE-REFLECTANCE; LIGHT-SCATTERING; TURBID MEDIA; SYSTEM; BRAIN;
D O I
10.1088/0957-0233/20/10/104020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper reviews the recent developments in the field of biomedical optical imaging, emphasizing technologies that have been moved from 'bench top to bedside'. Important new developments in this field allow for unprecedented visualization of the tissue microstructure and enable quantitative mapping of disease-specific endogenous and exogenous substances. With these advances, optical imaging technologies are becoming powerful clinical tools for non-invasive and objective diagnosis, guided treatment and monitoring therapies. Recent developments in visible and infrared diffuse spectroscopy and imaging, spectral imaging, optical coherence tomography, confocal imaging, molecular imaging and dynamic spectral imaging are presented together with their derivative medical devices. Their perspectives and challenges are discussed.
引用
收藏
页数:12
相关论文
共 70 条
[61]   Dynamic Spectral Imaging: Improving Colposcopy [J].
Soutter, William P. ;
Diakomanolis, Emmanuel ;
Lyons, Deirdre ;
Ghaem-Maghami, Sadaf ;
Ajala, Tosin ;
Haidopoulos, Dimitrios ;
Doumplis, Dimitrios ;
Kalpaktsoglou, Costas ;
Sakellaropoulos, Gerasimos ;
Soliman, Suzan ;
Perryman, Karen ;
Hird, Vicky ;
Buckley, C. Hilary ;
Pavlakis, Kitty ;
Markaki, Sofia ;
Dina, Roberto ;
Healy, Vourneen ;
Balas, Costas .
CLINICAL CANCER RESEARCH, 2009, 15 (05) :1814-1820
[62]   Near-infrared characterization of breast tumors in vivo using spectrally-constrained reconstruction [J].
Srinivasan, S ;
Pogue, BW ;
Brooksby, B ;
Jiang, SD ;
Dehghani, H ;
Kogel, C ;
Wells, WA ;
Poplack, SP ;
Paulsen, KD .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (05) :513-526
[63]   In vivo detection of human papilloma virus-induced lesions of anogenital area after application of acetic acid: a novel and accurate approach to a trivial method [J].
Stefanaki, IM ;
Tosca, AD ;
Themelis, GC ;
Vazgiouraki, EM ;
Dokianakis, DN ;
Panayiotidis, JG ;
Spandidos, DA ;
Balas, CJ .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2001, 65 (2-3) :115-121
[64]   Functional brain imaging by multi-wavelength time-resolved near infrared spectroscopy [J].
Torricelli, A. ;
Contini, D. ;
Pifferi, A. ;
Spinelli, L. ;
Cubeddu, R. .
OPTO-ELECTRONICS REVIEW, 2008, 16 (02) :131-135
[65]   Ensembles of radial basis function networks for spectroscopic detection of cervical precancer [J].
Tumer, K ;
Ramanujam, N ;
Ghosh, J ;
Richards-Kortum, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) :953-961
[66]   Shedding light onto live molecular targets [J].
Weissleder, Ralph ;
Ntziachristos, Vasilis .
NATURE MEDICINE, 2003, 9 (01) :123-128
[67]   Real-time in vivo imaging by high-speed spectral optical coherence tomography [J].
Wojtkowski, M ;
Bajraszewski, T ;
Targowski, P ;
Kowalczyk, A .
OPTICS LETTERS, 2003, 28 (19) :1745-1747
[68]   Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications [J].
Wolf, Martin ;
Ferrari, Marco ;
Quaresima, Valentina .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (06)
[69]   High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance [J].
Yang, VXD ;
Gordon, ML ;
Qi, B ;
Pekar, J ;
Lo, S ;
Seng-Yue, E ;
Mok, A ;
Wilson, BC ;
Vitkin, IA .
OPTICS EXPRESS, 2003, 11 (07) :794-809
[70]   Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo [J].
Zonios, G ;
Perelman, LT ;
Backman, VM ;
Manoharan, R ;
Fitzmaurice, M ;
Van Dam, J ;
Feld, MS .
APPLIED OPTICS, 1999, 38 (31) :6628-6637