Temporal patterns of paroxysmal atrial fibrillation following DDDR pacemaker implantation

被引:49
作者
Gillis, AM
Rose, MS
机构
[1] Foothills Prov Gen Hosp, Dept Med, Div Cardiol, Calgary, AB T2N 2T9, Canada
[2] Foothills Prov Gen Hosp, Dept Community Hlth Sci, Calgary, AB T2N 2T9, Canada
[3] Univ Calgary, Calgary, AB, Canada
基金
英国医学研究理事会;
关键词
D O I
10.1016/S0002-9149(00)00792-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Paroxysmal atrial fibrillation (AF) episodes have been reported to be randomly distributed. However, because patients are not always symptomatic, it has been difficult to study temporal patterns of AF, Newer implantable pulse generators have data-logging capabilities that permit the detection and analysis of temporal patterns of AF, This study tested the hypothesis that AF episodes occur in clusters over time and that these episodes ore not randomly distributed in individual patients. The date and time of 582 episodes of AF were recorded from the data logs of 16 patients with a Medtronic Thera DR followed 6 weeks and 6 and 12 months after pulse generator implant. The probability of AF recurrence and the interevent intervals between successive episodes of AF were fitted to monoexponential and Weibull distributions. A Weibull distribution best described the non-random distribution of AF for 67% of follow-vp visits. Temporal clustering of AF (interevent intervals <24 hours) declined during follow-up (95 +/- 10%, 90 +/- 11%, and 74 +/- 28% at the 6-week and 6- and 12-month visits, respectively; p < 0.05). The average duration of an episode of AF tended to increase over time (0.31 hour, 95% confidence intervals [Cl] 0.17 to 0.58 hours; 0.36 hours, 95% Cl 0.17 to 0.78 hours; 0.65 hours, 95% Cl 0.29 to 1.45 hours [p = 0,07] at the 6-week and 6- and 12-month visits, respectively). Paroxysmal AF recurrence is nonrandomly distributed over the long term in many patients. The temporal patterns of AF change over time offer pacemaker implantation. This has implications for the selection of study end points in AF clinical trials. (C) 2000 by Excerpta Medica, Inc.
引用
收藏
页码:1445 / 1450
页数:6
相关论文
共 17 条
  • [11] 2-O
  • [12] Is the atrial high rate episode diagnostic feature reliable in detecting paroxysmal episodes of atrial tachyarrhythmias?
    Seidl, K
    Meisel, E
    VanAgt, E
    Ottenhoff, F
    Hess, M
    Hauer, B
    Zahn, R
    Senges, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (04): : 694 - 700
  • [13] Risk factors for syncope recurrence after a positive tilt-table test in patients with syncope
    Sheldon, R
    Rose, S
    Flanagan, P
    Koshman, ML
    Killam, S
    [J]. CIRCULATION, 1996, 93 (05) : 973 - 981
  • [14] CHARACTERISTICS OF PATIENTS WITH NONFATAL CARDIAC-ARREST 3 TO 180 DAYS AFTER ACUTE MYOCARDIAL-INFARCTION
    SHELDON, RS
    WYSE, DG
    MITCHELL, LB
    GILLIS, AM
    KAVANAGH, KM
    DUFF, HJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (11) : 753 - 758
  • [15] ATRIAL-FIBRILLATION BEGETS ATRIAL-FIBRILLATION - A STUDY IN AWAKE CHRONICALLY INSTRUMENTED GOATS
    WIJFFELS, MCEF
    KIRCHHOF, CJHJ
    DORLAND, R
    ALLESSIE, MA
    [J]. CIRCULATION, 1995, 92 (07) : 1954 - 1968
  • [16] LONG-TERM TEMPORAL PATTERNS OF VENTRICULAR TACHYARRHYTHMIAS
    WOOD, MA
    SIMPSON, PM
    STAMBLER, BS
    HERRE, JM
    BERNSTEIN, RC
    ELLENBOGEN, KA
    [J]. CIRCULATION, 1995, 91 (09) : 2371 - 2377
  • [17] Appropriate use of the implantable cardioverter defibrillator: A Canadian perspective
    Yee, R
    Connolly, SJ
    Gillis, AM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 1 - 4