The cantilever and the tip are at the centerpiece of the AFM. Properties such as the cantilever stiffness and resonant frequency, tip shape and sharpness, and material characteristics determine the mode of operation of the AFM and the type of experiments and measurements that can be performed. The possibility of batch fabricating cantilevers has permitted the fabrication and characterization of specialized tips for a variety of experiments. We believe that the use of new materials and tip shapes will allow new applications for the AFM in the future.; The cantilever and the tip are at the centerpiece of the AFM. Properties such as the cantilever stiffness and resonant frequency, tip shape and sharpness, and material characteristics determine the mode of operation of the AFM and the type of experiments and measurements that can be performed. The possibility of batch fabricating cantilevers has permitted the fabrication and characterization of specialized tips for a variety of experiments. It is believed that the use of new materials and tip shapes will allow new applications for the AFM in the future.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 33 条
[1]   LOW-TEMPERATURE THERMAL-OXIDATION SHARPENING OF MICROCAST TIPS [J].
AKAMINE, S ;
QUATE, CF .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (05) :2307-2310
[2]   MICROFABRICATION OF CANTILEVER STYLI FOR THE ATOMIC FORCE MICROSCOPE [J].
ALBRECHT, TR ;
AKAMINE, S ;
CARVER, TE ;
QUATE, CF .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (04) :3386-3396
[3]   FREQUENCY-MODULATION DETECTION USING HIGH-Q CANTILEVERS FOR ENHANCED FORCE MICROSCOPE SENSITIVITY [J].
ALBRECHT, TR ;
GRUTTER, P ;
HORNE, D ;
RUGAR, D .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (02) :668-673
[4]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[5]   AFM probes with directly fabricated tips [J].
Boisen, A ;
Hansen, O ;
Bouwstra, S .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1996, 6 (01) :58-62
[6]   SILICON CANTILEVERS AND TIPS FOR SCANNING FORCE MICROSCOPY [J].
BRUGGER, J ;
BUSER, RA ;
DEROOIJ, NF .
SENSORS AND ACTUATORS A-PHYSICAL, 1992, 34 (03) :193-200
[7]   RESONANCE RESPONSE OF SCANNING FORCE MICROSCOPY CANTILEVERS [J].
CHEN, GY ;
WARMACK, RJ ;
THUNDAT, T ;
ALLISON, DP ;
HUANG, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (08) :2532-2537
[8]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405
[9]  
DENHARTOG JP, 1956, MECHANICAL VIBRATION
[10]   DIRECT MEASUREMENT OF COLLOIDAL FORCES USING AN ATOMIC FORCE MICROSCOPE [J].
DUCKER, WA ;
SENDEN, TJ ;
PASHLEY, RM .
NATURE, 1991, 353 (6341) :239-241