Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration

被引:38
作者
Manke, D
Rösch, P
Nehrke, K
Börnert, P
Dössel, O
机构
[1] Univ Karlsruhe, Inst Biomed Engn, D-76128 Karlsruhe, Germany
[2] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
关键词
coronary magnetic resonance angiography; image registration; prospective motion correction;
D O I
10.1109/TMI.2002.804428
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Image processing was used as a fundamental tool to derive motion information from magnetic resonance (MR) images, which was fed back into prospective respiratory motion correction during subsequent data acquisition to improve image quality in coronary MR angiography (CMRA) scans. This reduces motion artifacts in the images and, in addition, enables the usage of a broader gating window than commonly used today to increase the scan efficiency. The aim of the study reported in this paper was to find a suitable motion model to be used for respiratory motion correction in cardiac imaging and to develop a calibration procedure to adapt the motion model to the individual patient. At first, the performance of three motion models [one-dimensional translation in feet-head (FH) direction, three-dimensional (3-D) translation, and 3-D affine transformation] was tested in a small volunteer study. An elastic image registration algorithm was applied to 3-D MR images of the coronary vessels obtained at different respiratory levels. A strong intersubject variability was observed. The 3-D translation and affine transformation model were found to be superior over the conventional FH translation model used today. Furthermore, a new approach is presented, which utilizes a fast model-based image registration to extract motion information from time series of low-resolution 3-D MR images, which reflects the respiratory motion of the heart. The registration is based on a selectable global 3-D motion model (translation, rigid, or affine transformation). All 3-D MR images were registered with respect to end expiration. The resulting time series of model parameters were analyzed in combination with additionally acquired motion information from a diaphragmatic MR pencil-beam navigator to calibrate the respiratory motion model. To demonstrate the potential of a calibrated motion model for prospective motion correction in coronary imaging, the approach was tested in CMRA examinations in five volunteers.
引用
收藏
页码:1132 / 1141
页数:10
相关论文
共 28 条
  • [1] Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    Botnar, RM
    Stuber, M
    Danias, PG
    Kissinger, KV
    Manning, WJ
    [J]. CIRCULATION, 1999, 99 (24) : 3139 - 3148
  • [2] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696
  • [3] Dynamic scan-plane tracking using MR position monitoring
    Derbyshire, JA
    Wright, GA
    Henkelman, RM
    Hinks, RS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 924 - 932
  • [4] GONZALEZ RC, 1992, DIGITAL IMAGE PROCES, P51
  • [5] Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: Implications for slice-followed coronary artery imaging
    Keegan, J
    Gatehouse, P
    Yang, GZ
    Firmin, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 476 - 481
  • [6] KEEGAN J, 2001, P 9 ANN M ISMRM GLAS, P172
  • [7] A survey of hierarchical non-linear medical image registration
    Lester, H
    Arridge, SR
    [J]. PATTERN RECOGNITION, 1999, 32 (01) : 129 - 149
  • [8] Accelerated coronary MRA by simultaneous acquisition of multiple 3D stacks
    Manke, D
    Börnert, P
    Nehrke, K
    Nagel, E
    Dössel, O
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 478 - 483
  • [9] MANKE D, 2000, P 8 ANN M ISMRM DENV, P400
  • [10] Prospective adaptive navigator correction for breath-hold MR coronary angiography
    McConnell, MV
    Khasgiwala, VC
    Savord, BJ
    Chen, MH
    Chuang, ML
    Edelman, RR
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 148 - 152