Since the early 1990s, there has been a dramatic increase in modular total hip designs ranging from a stern with a proximal taper and modular head, to a distal stem, double taper proximal neck, and modular head. Clinical advantages of the modular neck include intraoperative adjusment of leg length via the neck-head taper and femoral anteversion via the neck-stern taper. Sixteen cases of a double tapered cone, Margron hip prosthesis, were presented for retrieval analysis. Macroscopic inspection, corrosion testing, light microscopy, and scanning electron microscopy were conducted to elucidate mechanisms of failure. In this regard, 6 neck components showed significant fretting, and crevice corrosion of the neck-stern taper with an average implantation time of 39 months compared with the remaining retrievals, which showed no corrosion with and average time in situ of 2.7 months. This retrieval Study demonstrates that even with a modern taper design and corrosion-resistant materials, increased modularity can lead to fretting and crevice corrosion, metal ion generation, and particulate debris that may contribute to periprosthetic osteolysis and loosening.
引用
收藏
页码:1019 / 1023
页数:5
相关论文
共 15 条
[1]
The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :9-14
[2]
COLLIER JP, 1995, CLIN ORTHOP RELAT RE, V311
[3]
CORROSION AND WEAR AT THE MODULAR INTERFACE OF UNCEMENTED FEMORAL STEMS [J].
COOK, SD ;
BARRACK, RL ;
CLEMOW, AJT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :68-72
[4]
Ducheyne PHGW., 1984, METAL CERAMIC BIOMAT
[5]
FROST RA, 2003, J ENG DES, V2
[6]
GOLDBERG JR, 2002, CLIN ORTHOP RELAT RE, V401
[7]
JACOBS JJ, 1995, CLIN ORTHOP RELAT RE, V319
[8]
JACOBS JJ, 1998, J BONE JOINT SURG AM, V80, P10
[9]
MCTIGHE T, CEMENTLESS MODULAR S
[10]
Modular hip stems: Determination of disassembly force of a neck-stem coupling [J].
Pallini, Francesco ;
Cristofolini, Luca ;
Traina, Francesco ;
Toni, Aldo .
ARTIFICIAL ORGANS, 2007, 31 (02) :166-170