Urea biosensor based on PANi(urease)-Nation®/Au composite electrode

被引:150
作者
Luo, YC [1 ]
Do, JS [1 ]
机构
[1] Tunghai Univ, Dept Chem Engn, Taichung 40704, Taiwan
关键词
urea sensor; urease; polyaniline-Nafion (R) composite electrode; cyclic voltammetry; ammonium ion;
D O I
10.1016/j.bios.2003.11.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The polyaniline (PANi)-Nafion(R) composite film was prepared onto the ceramic plate by the cyclic voltammetry (CV) method with the various cycle numbers. When the PANi-Nafion(R)/Au/ceramic plate with the preparing cycle number of 5 was as working electrode, the cathodic peak current was achieved as 84.0 muA in 60 mg dl(-1) NH4Cl buffer solution. On the other hand, the small cathodic peak currents for buffer solution in the presence of 60 mg dl(-1) LiOH, NaCl and KCl, respectively, were found with the same composite electrode as working electrode. The cathodic peak current decreased from 84.0 to 16.3 muA in the 60 mg dl(-1) NH4Cl buffer solution when the cycle number for preparing PANi-Nafion(R)/Au/ceramic plate composite electrode with the CV method increased from 5 to 15. The enzyme of urease was immobilized onto the PANi-Nafion(R)/Au/ceramic plate composite film by the electrochemical immobilization and the casting methods and used as sensing electrode to detect the concentration of urea in the buffer solution. The sensitivity of composite electrode immobilized with the casting method was greater than that of electrochemical immobilization method. The sensitivity and the detecting limit of the urea sensor were found to be 0.7 and 5.27 muA (mg dl(-1))(-1) cm(-2), as well as 6 and 0.3 mg dl(-1), respectively, when urease was immobilized by glutaraldehyde (GA) cross-linker and Nafion(R) network, respectively. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 21 条
  • [1] Polypyrrole-based amperometric flow injection biosensor for urea
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) : 107 - 113
  • [2] Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) : 155 - 160
  • [3] Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline-poly(n-butyl methacrylate) composites
    Castillo-Ortega, MM
    Rodriguez, DE
    Encinas, JC
    Plascencia, M
    Méndez-Velarde, FA
    Olayo, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) : 19 - 25
  • [4] An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode
    Cho, WJ
    Huang, HJ
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3946 - 3951
  • [5] Application of a polyaniline based ammonium sensor for the amperometric immunoassay of a urease conjugated Tal 1 protein
    Deng, AP
    Cheng, JT
    Huang, HJ
    [J]. ANALYTICA CHIMICA ACTA, 2002, 461 (01) : 49 - 55
  • [6] A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer
    Eggenstein, C
    Borchardt, M
    Diekmann, C
    Gründig, B
    Dumschat, C
    Cammann, K
    Knoll, M
    Spener, F
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) : 33 - 41
  • [7] COMPARISON OF POTENTIOMETRIC ENZYME SENSORS FOR UREA AND PENICILLIN-G - DIFFERENTIAL THICK-FILM SENSORS VERSUS CLASSICAL ELECTRODES
    EPPELSHEIM, C
    AUBECK, R
    HAMPP, N
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1995, 100 (02) : 131 - 137
  • [8] Application of conducting polymers to biosensors
    Gerard, M
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) : 345 - 359
  • [9] Development of a urea biosensor based on a polymeric membrane including zeolite
    Hamlaoui, ML
    Reybier, K
    Marrakchi, M
    Jaffrezic-Renault, N
    Martelet, C
    Kherrat, R
    Walcarius, A
    [J]. ANALYTICA CHIMICA ACTA, 2002, 466 (01) : 39 - 45
  • [10] FET-based sensors with robust photosensitive polymer membranes for detection of ammonium ions and urea
    Kazanskaya, N
    Kukhtin, A
    Manenkova, M
    Reshetilov, N
    Yarysheva, L
    Arzhakova, O
    Volynskii, A
    Bakeyev, N
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (03) : 253 - 261