Using Doppler signal power to detect changes in vessel size: A feasibility study using a wall-less flow phantom

被引:7
作者
Deverson, S [1 ]
Evans, DH [1 ]
机构
[1] Univ Leicester, Fac Med, Div Med Phys, Leicester, Leics, England
关键词
transcranial Doppler ultrasound; Doppler signal power; flow phantom; beam shape; filtering;
D O I
10.1016/S0301-5629(99)00148-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The power of a Doppler signal is theoretically proportional to the volume of blood within the sample volume of an ultrasound (US) beam and, hence, mag provide a means of detecting in vivo changes in the cross-sectional area of cerebral vessels, such as the middle cerebral artery, The purpose of this study was to examine the relationship between power and vessel size for signals recorded from a wall-less flow phantom, The results demonstrate the importance for the in vitro case of maximising the received signal power for each channel to obtain the true relationship between power and size, and show that a nonproportional relationship observed between the two parameters is primarily caused by high-pass filtering and nonuniform insonation, In addition, an investigation of the reproducibility of power values after transducer repositioning has shown that variation occurs even when extreme care is taken to maximise the received signal intensity. The implications of these results for the in vivo use of the Doppler signal power method are discussed. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:593 / 602
页数:10
相关论文
共 46 条
  • [11] A PULSE-FOOT-SEEKING ALGORITHM FOR DOPPLER ULTRASOUND WAVEFORMS
    EVANS, DH
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (03): : 267 - 271
  • [12] ACOUSTICAL PROPERTIES OF HUMAN SKULL
    FRY, FJ
    BARGER, JE
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (05) : 1576 - 1590
  • [13] CEREBRAL BLOOD-FLOW IN THE NEWBORN-INFANT - COMPARISON OF DOPPLER ULTRASOUND AND XE-133 CLEARANCE
    GREISEN, G
    JOHANSEN, K
    ELLISON, PH
    FREDRIKSEN, PS
    MALI, J
    FRIISHANSEN, B
    [J]. JOURNAL OF PEDIATRICS, 1984, 104 (03) : 411 - 418
  • [14] Grolimund P, 1986, TRANSCRANIAL DOPPLER, P10
  • [15] SIMULTANEOUS MEASUREMENTS OF CEREBRAL-CIRCULATION WITH ELECTROMAGNETIC FLOWMETRY AND DOPPLER ULTRASOUND VELOCITY IN THE NEWBORN PIG
    HAALAND, K
    KARLSSON, B
    SKOVLUND, E
    THORESEN, M
    [J]. PEDIATRIC RESEARCH, 1994, 36 (05) : 601 - 606
  • [16] HANSEN NB, 1983, PEDIATRICS, V72, P526
  • [17] HARER C, 1995, J NEUROIMAGING, V5, pS86
  • [18] Evaluation of cerebral arterial flow with transcranial Doppler ultrasound: Theoretical development and phantom studies
    Hatab, MR
    Giller, CA
    Clarke, GD
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) : 1025 - 1031
  • [19] KONTOS HA, 1989, STROKE, V20, P1
  • [20] TRANSCRANIAL DOPPLER IS VALID FOR DETERMINATION OF THE LOWER LIMIT OF CEREBRAL BLOOD-FLOW AUTOREGULATION
    LARSEN, FS
    OLSEN, KS
    HANSEN, BA
    PAULSON, OB
    KNUDSEN, GM
    [J]. STROKE, 1994, 25 (10) : 1985 - 1988