Effects of transvenous electrode polarity and waveform duration on the relationship between defibrillation threshold and upper limit of vulnerability

被引:19
作者
Huang, J
KenKnight, BH
Walcott, GP
Rollins, DL
Smith, WM
Ideker, RE
机构
[1] UNIV ALABAMA,DEPT MED,DIV CARDIOVASC DIS,CARDIAC RHYTHM MANAGEMENT LAB,BIRMINGHAM,AL 35294
[2] CARDIAC PACEMAKERS INC,ST PAUL,MN
关键词
defibrillation; electrical stimulation; fibrillation;
D O I
10.1161/01.CIR.96.4.1351
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The upper limit of vulnerability (ULV) hypothesis for defibrillation predicts that maneuvers that alter the ULV will cause a similar alteration in the defibrillation threshold (DFT). The purpose of this study was to test this prediction by evaluating the effects of electrode polarity and waveform duration on the relationship between the DFT and the ULV. Methods and Results Platinum spring electrodes were placed in the right ventricular (RV) apex and the superior vena cava in 12 pigs. Strength-duration curves were constructed for the DFT and ULV for each electrode polarity with monophasic waveforms (6 pigs) of different durations (2 to 14 ms) and biphasic truncated exponential waveforms (6 pigs) having phase 1 equal to 4 ms and phase 2 of different durations (0 to 10 ms). ULV data were gathered by scanning of the T wave. The ventricular pacing threshold (VPT) and ventricular fibrillation threshold (VFT) were also determined with these same waveforms. For the RV electrode as a cathode for monophasic and the first phase of biphasic stimuli, VPTs for the same waveform duration were significantly lower than for the configuration with the RV electrode as an anode. VFTs were not significantly different for the two electrode polarities with either monophasic or biphasic waveforms. The DFT changed in a fashion similar to the ULV with changes in electrode polarity and phase duration for both monophasic and biphasic waveforms. The ULV and DFT for each waveform duration for each polarity were strongly correlated (r=.83 to .99). Conclusions The almost identical changes in ULV and DFT with changes in electrode polarity and waveform duration provide new evidence to support the ULV hypothesis of defibrillation.
引用
收藏
页码:1351 / 1359
页数:9
相关论文
共 43 条
[1]  
BACON ME, 1992, PACE, V15, P530
[2]   EVALUATION OF ELECTRODE POLARITY ON DEFIBRILLATION EFFICACY [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
GREENE, HL .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (07) :433-437
[3]   EFFECTS OF PACING RATE AND TIMING OF DEFIBRILLATION SHOCK ON THE RELATION BETWEEN THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VULNERABILITY IN OPEN CHEST DOGS [J].
CHEN, PS ;
FELD, GK ;
MOWER, MM ;
PETERS, BB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (06) :1555-1563
[4]   RELATION BETWEEN UPPER LIMIT OF VULNERABILITY AND DEFIBRILLATION THRESHOLD IN HUMANS [J].
CHEN, PS ;
FELD, GK ;
KRIETT, JM ;
MOWER, MM ;
TARAZI, RY ;
FLECK, RP ;
SWERDLOW, CD ;
GANG, ES ;
KASS, RM .
CIRCULATION, 1993, 88 (01) :186-192
[5]   MECHANISM OF VENTRICULAR VULNERABILITY TO SINGLE PREMATURE STIMULI IN OPEN-CHEST DOGS [J].
CHEN, PS ;
WOLF, PD ;
DIXON, EG ;
DANIELEY, ND ;
FRAZIER, DW ;
SMITH, WM ;
IDEKER, RE .
CIRCULATION RESEARCH, 1988, 62 (06) :1191-1209
[6]   COMPARISON OF THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VENTRICULAR VULNERABILITY [J].
CHEN, PS ;
SHIBATA, N ;
DIXON, EG ;
MARTIN, RO ;
IDEKER, RE .
CIRCULATION, 1986, 73 (05) :1022-1028
[7]   OPTICAL RECORDINGS IN THE RABBIT HEART SHOW THAT DEFIBRILLATION STRENGTH SHOCKS PROLONG THE DURATION OF DEPOLARIZATION AND THE REFRACTORY PERIOD [J].
DILLON, SM .
CIRCULATION RESEARCH, 1991, 69 (03) :842-856
[8]   SYNCHRONIZED REPOLARIZATION AFTER DEFIBRILLATION SHOCKS - A POSSIBLE COMPONENT OF THE DEFIBRILLATION PROCESS DEMONSTRATED BY OPTICAL RECORDINGS IN RABBIT HEART [J].
DILLON, SM .
CIRCULATION, 1992, 85 (05) :1865-1878
[9]   EFFECTS OF THE PACING SITE, PROCAINAMIDE, AND LEAD CONFIGURATION ON THE RELATIONSHIP BETWEEN THE UPPER LIMIT OF VULNERABILITY AND THE DEFIBRILLATION THRESHOLD [J].
FAN, W ;
GOTOH, M ;
CHEN, PS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06) :1279-1284
[10]   Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system [J].
Huang, J ;
KenKnight, BH ;
Walcott, GP ;
Walker, RG ;
Smith, WA ;
Ideker, RE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (02) :161-171