A new amperometric glucose biosensor based on platinum nanoparticles/polymerized ionic liquid-carbon nanotubes nanocomposites

被引:56
作者
Chu, Xiaochen [1 ]
Wu, Bohua [1 ]
Xiao, Chunhui [1 ]
Zhang, Xiaohua [1 ]
Chen, Jinhua [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
Polymerized ionic liquid; Platinum nanoparticles; Glucose oxidase; Glucose; Amperometry; GLASSY-CARBON; MODIFIED ELECTRODE; OXIDASE; CODEPOSITION; PALLADIUM; NAFION; FILM;
D O I
10.1016/j.electacta.2009.12.057
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A new amperometric glucose biosensor has been developed based on platinum (Pt) nanoparticles/polymerized ionic liquid-carbon nanotubes (CNTs) nanocomposites (PtNPs/PIL-CNTs). The CNTs was functionalized with polymerized ionic liquid (PIL) through directly polymerization of the ionic liquid, 1-vinyl-3-ethylimidazolium tetrafluoroborate ([VEIM]BF4), on carbon nanotubes and then used as the support for the highly dispersed Pt nanoparticles. The electrochemical performance of the PtNPs/PIL-CNTs modified glassy carbon (PtNPs/PIL-CNTs/GC) electrode has been investigated by typical electrochemical methods. The PtNPs/PIL-CNTs/GC electrode shows high electrocatalytic activity towards the oxidation of hydrogen peroxide. Taking glucose oxidase (GOD) as the model, the resulting amperometric glucose biosensor shows good analytical characteristics, such as a high sensitivity (28.28 mu A mM(-1) cm(-2)), wide linear range (up to 12 mM) and low detection limit (10 mu M). (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2848 / 2852
页数:5
相关论文
共 24 条
[1]   Amperometric glucose biosensor based on boron-doped carbon nanotubes modified electrode [J].
Chen, Xiaoli ;
Chen, Jinhua ;
Deng, Chunyan ;
Xiao, Chunhui ;
Yang, Yanmin ;
Nie, Zhou ;
Yao, Shouzhuo .
TALANTA, 2008, 76 (04) :763-767
[2]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[3]  
DAN W, 2009, TALANTA, V79, P1233
[4]   Carbon nanotube/gold nanoparticles/polyethylenimine-functionalized ionic liquid thin film composites for glucose biosensing [J].
Jia, Fei ;
Shan, Changsheng ;
Li, Fenghua ;
Niu, Li .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :945-950
[5]  
KEITH BM, 2007, ANALYST, V132, P1254
[6]   Electrochemical characteristics of glucose oxidase adsorbed at carbon nanotubes modified electrode with ionic liquid as binder [J].
Liu, Ying ;
Liu, Ling ;
Dong, Shaojun .
ELECTROANALYSIS, 2007, 19 (01) :55-59
[7]   Amperometric glucose biosensor based on polymerized ionic liquid microparticles [J].
Lopez, M. Sanchez-Paniagua ;
Mecerreyes, D. ;
Lopez-Cabarcos, E. ;
Lopez-Ruiz, B. .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (12) :2320-2328
[8]  
Miscoria SA, 2002, ELECTROANAL, V14, P981, DOI 10.1002/1521-4109(200208)14:14<981::AID-ELAN981>3.0.CO
[9]  
2-1
[10]   Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes [J].
Musameh, M ;
Wang, J ;
Merkoci, A ;
Lin, YH .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (10) :743-746