Quantifying instrument errors in macromolecular X-ray data sets

被引:68
作者
Diederichs, Kay [1 ]
机构
[1] Univ Konstanz, Fac Biol, D-78457 Constance, Germany
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2010年 / 66卷
关键词
INTEGRATION;
D O I
10.1107/S0907444910014836
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An indicator which is calculated after the data reduction of a test data set may be used to estimate the (systematic) instrument error at a macromolecular X-ray source. The numerical value of the indicator is the highest signal-to-noise [I/sigma(I)] value that the experimental setup can produce and its reciprocal is related to the lower limit of the merging R factor. In the context of this study, the stability of the experimental setup is influenced and characterized by the properties of the X-ray beam, shutter, goniometer, cryostream and detector, and also by the exposure time and spindle speed. Typical values of the indicator are given for data sets from the JCSG archive. Some sources of error are explored with the help of test calculations using SIM_MX [Diederichs (2009), Acta Cryst. D65, 535-542]. One conclusion is that the accuracy of data at low resolution is usually limited by the experimental setup rather than by the crystal. It is also shown that the influence of vibrations and fluctuations may be mitigated by a reduction in spindle speed accompanied by stronger attenuation.
引用
收藏
页码:733 / 740
页数:8
相关论文
共 22 条
[1]   PHENIX: a comprehensive Python']Python-based system for macromolecular structure solution [J].
Adams, Paul D. ;
Afonine, Pavel V. ;
Bunkoczi, Gabor ;
Chen, Vincent B. ;
Davis, Ian W. ;
Echols, Nathaniel ;
Headd, Jeffrey J. ;
Hung, Li-Wei ;
Kapral, Gary J. ;
Grosse-Kunstleve, Ralf W. ;
McCoy, Airlie J. ;
Moriarty, Nigel W. ;
Oeffner, Robert ;
Read, Randy J. ;
Richardson, David C. ;
Richardson, Jane S. ;
Terwilliger, Thomas C. ;
Zwart, Peter H. .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2010, 66 :213-221
[2]   THE CCP4 SUITE - PROGRAMS FOR PROTEIN CRYSTALLOGRAPHY [J].
BAILEY, S .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1994, 50 :760-763
[3]  
Bevington P. R., 1969, DATA REDUCTION ERROR
[4]   Measurement errors and their consequences in protein crystallography [J].
Borek, D ;
Minor, W ;
Otwinowski, Z .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2003, 59 :2031-2038
[5]   A quantitative approach to data-collection strategies [J].
Bourenkov, GP ;
Popov, AN .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :58-64
[6]   Carrying out an optimal experiment [J].
Dauter, Zbigniew .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2010, 66 :389-392
[7]   Simulation of X-ray frames from macromolecular crystals using a ray-tracing approach [J].
Diederichs, Kay .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2009, 65 :535-542
[8]   Scaling and assessment of data quality [J].
Evans, P .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :72-82
[9]   PILATUS: A single photon counting pixel detector for X-ray applications [J].
Henrich, B. ;
Bergamaschi, A. ;
Broennimann, C. ;
Dinapoli, R. ;
Eikenberry, E. F. ;
Johnson, I. ;
Kobas, M. ;
Kraft, P. ;
Mozzanica, A. ;
Schmitt, B. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :247-249
[10]   Exploration of Uncharted Regions of the Protein Universe [J].
Jaroszewski, Lukasz ;
Li, Zhanwen ;
Krishna, S. Sri ;
Bakolitsa, Constantina ;
Wooley, John ;
Deacon, Ashley M. ;
Wilson, Ian A. ;
Godzik, Adam .
PLOS BIOLOGY, 2009, 7 (09)