DNA probe attachment on plastic surfaces and microfluidic hybridization array channel devices with sample oscillation

被引:59
作者
Liu, YJ [1 ]
Rauch, CB [1 ]
机构
[1] Motorola Inc, Phys Sci Res Labs, Motorola Labs, Tempe, AZ 85284 USA
关键词
DNA; surface attachment; hybridization kinetics; microfluidics; plastic; fabrication;
D O I
10.1016/S0003-2697(03)00051-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
DNA probe immobilization on plastic surfaces and device assembly are both critical to the fabrication of microfluidic hybridization array channel (MHAC) devices. Three oligonucleotide (oligo) probe immobilization procedures were investigated for attaching oligo probes on four different types of plastic surfaces (polystyrene, polycarbonate, poly(methylmethacrylate), and polypropylene). These procedures are the Surmodics procedure, the cetyltrimethylammonium bromide (CTAB) procedure, and the Reacti-Bind procedure. To determine the optimal plastic substrate and attachment chemistry for array fabrication, we investigated plastic hydrophobicity, intrinsic fluorescence, and oligo attachment efficiency. The Reacti-Bind procedure is least effective for attaching oligo probes in the microarray format. The CTAB procedure performs well enough to use in array fabrication, and the concentration of CTAB has a significant effect on oligo immobilization efficiency. We also found that use of amine-modified oligo probes resulted in better immobilization efficiency than use of unmodified oligos with the CTAB procedure. The oligo probe immobilization on plastic surfaces by the Surmodics procedure is the most effective with regard to probe spot quality and hybridization sensitivity. A DNA hybridization assay on such a device results in a limit of detection of 12 pM. Utilizing a CO2 IR laser machining and adhesive layer approach. we have developed an improved procedure for realizing a DNA microarray inside a microfluidic channel. This device fabrication procedure allows for more feasible spot placement in the channel and reduced sample adsorption by adhesive tapes used in the fabrication procedure. We also demonstrated improved hybridization kinetics and increased detection sensitivity in MHAC devices by implementing sample oscillation inside the channel. A limit of detection of 5 pM has been achieved in MHAC devices with sample oscillation. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:76 / 84
页数:9
相关论文
共 28 条
[1]  
[Anonymous], MICROSYST TECHNOL
[2]   Microfluidic devices for μ-TAS applications fabricated by polymer hot embossing [J].
Becker, H ;
Dietz, W .
MICROFLUIDIC DEVICES AND SYSTEMS, 1998, 3515 :177-182
[3]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[4]  
Cortese J, 2000, SCIENTIST, V14, P25
[5]   Flexible use of high-density oligonucleotide arrays for single-nucleotide polymorphism discovery and validation [J].
Dong, SL ;
Wang, E ;
Hsie, L ;
Cao, YX ;
Chen, XG ;
Gingeras, TR .
GENOME RESEARCH, 2001, 11 (08) :1418-1424
[6]  
DURAN L, 1999, 5858653 SURM INC
[7]   LIGHT-DIRECTED, SPATIALLY ADDRESSABLE PARALLEL CHEMICAL SYNTHESIS [J].
FODOR, SPA ;
READ, JL ;
PIRRUNG, MC ;
STRYER, L ;
LU, AT ;
SOLAS, D .
SCIENCE, 1991, 251 (4995) :767-773
[8]   DNA chips: promising toys have become powerful tools [J].
Gerhold, D ;
Rushmore, T ;
Caskey, CT .
TRENDS IN BIOCHEMICAL SCIENCES, 1999, 24 (05) :168-173
[9]   Why pharmacogenomics? Why now? [J].
Housman, D ;
Ledley, FD .
NATURE BIOTECHNOLOGY, 1998, 16 (06) :492-493
[10]   MICROPLATE HYBRIDIZATION OF AMPLIFIED VIRAL-DNA SEGMENT [J].
INOUYE, S ;
HONDO, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (06) :1469-1472