Behaviour of semipermeable membrane devices in neutral pesticide uptake from waters

被引:16
作者
Esteve-Turrillas, Francesc A. [1 ]
Pastor, Agustin [1 ]
de la Guardia, Miguel [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
Semipermeable membrane devices; Pesticide residues; Tandem mass spectrometry; Water analysis;
D O I
10.1007/s00216-006-1087-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of semipermeable membrane devices (SPMDs) has been evaluated as a passive sampler for the collection of multiresidue pesticides in continental waters. Seven chlorinated, five organophosphorus, six carbamate, nine pyrethroid and ten other pesticides were tested in order to estimate which compounds can be retained with these devices. The effect of water parameters, such as temperature, pH, ionic strength and organic matter content, were evaluated for their effect on the retention of the pesticides by the SPMDs. Studies of uptake from water were performed in a glass beaker containing 2 L distilled water spiked with 50 ng L-1 of each pesticide investigated. A SPMD was put in the beaker, under turbulent conditions, and analysed after 2 days' extraction. The contents of each SPMD were microwave-assisted-extracted twice with 30 mL hexane-acetone, to 90 degrees C for 10 min, and this was followed by a cleanup based on acetonitrile partitioning and solid-phase extraction. Gas chromatography with tandem mass spectrometry detection was employed for determination of pesticides, and provided low limits of detection from 0.5 to 7 ng per SPMD. Higher absorption rates were observed for pyrethroid, organophosphorus and chlorinated compounds than for carbamates. Pesticide uptake rates were independent of the water composition and decreased at low temperature.
引用
收藏
页码:2153 / 2162
页数:10
相关论文
共 40 条
[1]  
[Anonymous], 2001, MERCK IND
[2]  
Bergqvist P.-A., 1993, Analytical Proceedings, V30, P404, DOI 10.1039/ap9933000404
[3]   Polychlorinated biphenyls and hexachlorobenzene in atmosphere, sea-surface microlayer, and water measured with semi-permeable membrane devices (SPMDs) [J].
Booij, K ;
van Drooge, BL .
CHEMOSPHERE, 2001, 44 (02) :91-98
[4]   DETECTION OF AROCLOR, DDT, MALATHION AND HCB USING SEMIPERMEABLE MEMBRANES AS CONCENTRATION METHOD [J].
DELATORRE, AI ;
FERNANDEZ, C ;
TARAZONA, JV ;
MUNOZ, MJ .
CHEMOSPHERE, 1995, 31 (02) :2727-2737
[5]  
ELLIS GS, 1995, ENVIRON TOXICOL CHEM, V14, P1875, DOI [10.1897/1552-8618(1995)14[1875:EOLSMD]2.0.CO
[6]  
2, 10.1002/etc.5620141109]
[7]   Microwave-assisted extraction of pyrethroid insecticides from semi permeable membrane devices (SPMDs) used to indoor air monitoring [J].
Esteve-Turrillas, FA ;
Pastor, A ;
de la Guardia, M .
ANALYTICA CHIMICA ACTA, 2006, 560 (1-2) :118-127
[8]   Comparison of different mass spectrometric detection techniques in the gas chromatographic analysis of pyrethroid insecticide residues in soil after microwave-assisted extraction [J].
Esteve-Turrillas, FA ;
Pastor, A ;
de la Guardia, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (03) :801-809
[9]   Determination of pyrethroid insecticide residues in vegetable oils by using combined solid-phases extraction and tandem mass spectrometry detection [J].
Esteve-Turrillas, FA ;
Pastor, A ;
de la Guardia, M .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :50-57
[10]   Microwave-assisted extraction of pyrethroid insecticides from soil [J].
Esteve-Turrillas, FA ;
Aman, CS ;
Pastor, A ;
de la Guardia, A .
ANALYTICA CHIMICA ACTA, 2004, 522 (01) :73-78