In vivo safe catheter visualization and slice tracking using an optically detunable resonant marker

被引:41
作者
Weiss, S
Kuehne, T
Brinkert, F
Krombach, G
Katoh, M
Schaeffter, T
Guenther, RW
Buecker, A
机构
[1] Philips Res Labs, Dept Tech Syst, D-22335 Hamburg, Germany
[2] German Heart Inst, Dept Pediat Cardiol & Congenital Heart Dis, Berlin, Germany
[3] Univ Hosp Eppendorf, Dept Pediat Cardiol, Hamburg, Germany
[4] Univ Technol, Dept Diagnost Radiol, Aachen, Germany
关键词
interventional MRI; catheter tracking; catheter visualization; safety;
D O I
10.1002/mrm.20214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to test the in vivo feasibility of safe automatic catheter tracking based on an optically detunable resonant marker installed on the catheter tip, and also to test the compatibility of this approach with guidewire materials. The design of the resonant marker and the integration into the real-time MR environment is described. The catheter was used for real-time MR-guided catheterization of the aorta, left ventricle, and carotid in two swine. For in-plane visualization, the marker was repeatedly detuned. For automatic slice tracking, a projection difference measurement including detuning was interleaved with the imaging sequence. In vitro experiments were conducted to investigate the RF-safety of the marker and the effect of the guidewires on the signal intensity. For all orientations the marker provided excellent in vivo contrast using a radial steady-state free-precession sequence. Flashing of the marker by repetitive tuning/detuning further improved the inplane visualization. Automatic slice tracking during real-time imaging was successfully performed. The plastic guidewires did not interfere with the marker, and detuning by guidewires containing nitinol could be compensated. In conclusion, automatic slice tracking as well as excellent in-plane visualization can be achieved with this approach and it is safe with respect to FIF transmission. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:860 / 868
页数:9
相关论文
共 34 条
[1]  
Ackerman JL., 1986, Proceedings of the 5th Annual Meeting of ISMRM, P1131
[2]  
Athey T W, 1998, Magn Reson Imaging Clin N Am, V6, P791
[3]   Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[4]  
Burl M, 1996, MAGNET RESON MED, V36, P491, DOI 10.1002/mrm.1910360326
[5]  
CORDIS CORP, 1998, Patent No. 9855016
[6]  
CORDIS CORP, 1998, Patent No. 9842268
[7]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[8]  
Eggers H, 2003, MAGNET RESON MED, V49, P1163, DOI [10.1002/mrm.10459, 10.1002/mrm.10469]
[9]   Catheter visualization using locally induced, actively controlled field inhomogeneities [J].
Glowinski, A ;
Adam, G ;
Bucker, A ;
Neuerburg, J ;
vanVaals, JJ ;
Gunther, RW .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :253-258
[10]  
Konings MK, 2000, J MAGN RESON IMAGING, V12, P79, DOI 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.3.CO