Investigation of a high-efficiency nebulizer and a thimble glass frit nebulizer for elemental analysis of biological materials by inductively coupled plasma-atomic emission spectrometry

被引:38
作者
Liu, HY
Clifford, RH
Dolan, SP
Montaser, A
机构
[1] GEORGE WASHINGTON UNIV,DEPT CHEM,WASHINGTON,DC 20052
[2] US FDA,ELEMENTAL RES BRANCH,WASHINGTON,DC 20204
关键词
biological material; core nebulizer; demountable thimble glass frit nebulizer; detection limit; high-efficiency nebulizer; inductively coupled plasma atomic emission spectrometry; thimble frit nebulizer;
D O I
10.1016/0584-8547(95)01423-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A high-efficiency nebulizer (HEN) and a demountable thimble glass frit nebulizer are evaluated for argon inductively coupled plasma-atomic emission spectrometry (Ar ICP-AES). Aerosol characteristics for the HEN and the thimble frit are studied using laser Fraunhofer diffraction. Analyte transport efficiencies, mass transport rates, detection limits, and short- and long-term stabilities are measured. Four standard reference materials (trace elements in water, oyster tissue, bovine liver, and orchard leaves) are analyzed. For comparison, results obtained by a high-solid pneumatic nebulizer (conespray nebulizer) are also presented. Transport efficiencies of up to 50-60% are obtained for the HEN and the thimble frit nebulizer at an uptake rate of 11 mu l min(-1). For the elements tested. short- and long-term precisions and detection limits obtained with the thimble frit are comparable to those of a commonly used pneumatic nebulizer. Good agreement with certified values is obtained for six trace elements in a standard reference material (SRM) water sample nebulized by the thimble frit. However, signal suppression is observed when the biological or plant SRMs are nebulized with the thimble frit nebulizer. In contrast, satisfactory results are obtained for the same matrices when the HEN and the conespray nebulizer are used.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 43 条
[31]   INDUCTIVELY-COUPLED PLASMA OPTICAL-EMISSION SPECTROMETRY USING NEBULIZERS WITH WIDELY DIFFERENT SAMPLE CONSUMPTION RATES [J].
OLESLK, JW ;
KINZER, JA ;
HARKLEROAD, B .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2022-2030
[32]   SIMPLE EXPERIMENTS FOR THE CONTROL, THE EVALUATION AND THE DIAGNOSIS OF INDUCTIVELY-COUPLED PLASMA SEQUENTIAL SYSTEMS [J].
POUSSEL, E ;
MERMET, JM ;
SAMUEL, O .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (6-7) :743-755
[35]   MEASUREMENT OF AEROSOL TRANSPORT EFFICIENCY IN ATOMIC SPECTROMETRY [J].
SMITH, DD ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :533-537
[36]  
SMITH FG, 1991, ANAL CHEM, V63, P2626
[37]  
TAN H, 1992, 19 ANN M FED AN CHEM
[38]   MICROFLOW ULTRASONIC NEBULIZER FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
TARR, MA ;
ZHU, GX ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1689-1695
[39]   TRANSPORT EFFECTS WITH DRIBBLE AND JET ULTRASONIC NEBULIZERS [J].
TARR, MA ;
ZHU, GX ;
BROWNER, RF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :813-817
[40]  
WANG L, UNPUB ANAL CHEM