The effect of weight change on total body dual-energy X-ray absorptiometry: Results from a clinical trial

被引:18
作者
Blake, GM [1 ]
Herd, RJM [1 ]
Patel, R [1 ]
Fogelman, I [1 ]
机构
[1] Guys Hosp, Dept Nucl Med, London SE1 9RT, England
关键词
bone density; clinical trials; dual-energy X-ray absorptiometry; total body DXA; weight change;
D O I
10.1007/s001980070041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the past decade dual-energy X-ray absorptiometry (DXA) scanning has assumed an important role in the evaluation of new treatments for osteoporosis. Although the spine and hip are the sites usually chosen for monitoring bone mineral density (BMD) changes, total body DXA is also of interest because of the comprehensive view it gives of the whole skeleton. However, recent studies have reported anomalies in total body DXA in subjects undergoing weight change, suggesting that the technique may not be valid in this circumstance. The present study evaluated total body DXA in a trial of cyclical etidronate therapy in which many subjects underwent significant weight change. The study population was 152 postmenopausal women who had spine, hip and total body DXA scans performed at baseline, 1 and 2 years. The total body scans were analyzed using two software options referred to as 'standard' and 'enhanced'. The following variables were studied: total body BMD, total body bone mineral content (BMC), and subregional BMD values for the following seven sites: lumbar spine, thoracic spine, pelvis, head, ribs, arms and legs. The percentage change from baseline was analyzed in a multivariate regression analysis to derive the treatment effect (defined as the difference in changes between the etidronate and placebo groups) and a coefficient that described the effect of weight change on the total body DXA variable. Mean weight change after 2 years was +1.1 kg (range -9.3 to +16.8 kg). Results for the weight change coefficient were significantly different from zero for five of nine total body variables using the standard analysis and seven of nine for the enhanced analysis with values land standard errors) that varied from +0.67 (0.04) %/kg for standard total body BMC to - 0.32 (0.11) %/kg for enhanced arm BMD. Results for the treatment effect at 2 years were significantly different from zero for total body BMD, total body BMC and for the lumbar spine, thoracic spine and pelvis BMD subregions, but were not significant for head, rib, arm or leg BMD. Findings for the standard and enhanced analyses agreed closely and the size of the treatment effect was related to the proportion of trabecular bone at the measurement site. We conclude that in a randomized study the effects of weight change can be corrected and total body DXA can give useful information about the response to treatment across the whole skeleton.
引用
收藏
页码:832 / 839
页数:8
相关论文
共 32 条
[21]   DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR TOTAL-BODY AND REGIONAL BONE-MINERAL AND SOFT-TISSUE COMPOSITION [J].
MAZESS, RB ;
BARDEN, HS ;
BISEK, JP ;
HANSON, J .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (06) :1106-1112
[22]   Fractures attributable to osteoporosis: Report from the National Osteoporosis Foundation [J].
Melton, LJ ;
Thamer, M ;
Ray, NF ;
Chan, JK ;
Chesnut, CH ;
Einhorn, TA ;
Johnston, CC ;
Raisz, LG ;
Silverman, SL ;
Siris, ES .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :16-23
[23]  
Pritchard JE, 1996, INT J OBESITY, V20, P513
[24]   Bone densitometry: A new, highly responsive region of interest in the distal forearm to monitor the effect of osteoporosis treatment [J].
Ravn, P ;
Alexandersen, P ;
Mollgaard, A .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (04) :277-283
[25]   Medical expenditures for the treatment of osteoporotic fractures in the United States in 1995: Report from the national osteoporosis foundation [J].
Ray, NF ;
Chan, JK ;
Thamer, M ;
Melton, LJ .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :24-35
[26]   Hologic QDR 2000 whole-body scans: A comparison of three combinations of scan modes and analysis software [J].
Spector, E ;
LeBlanc, A ;
Shackelford, L .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (06) :440-445
[27]   ACCURACY OF MEASUREMENTS OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY INVIVO [J].
SVENDSEN, OL ;
HAARBO, J ;
HASSAGER, C ;
CHRISTIANSEN, C .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (05) :605-608
[28]  
SVENDSEN OL, 1995, J BONE MINER RES, V10, P868
[29]  
TOTHILL P, 1994, EUR J CLIN NUTR, V48, P781
[30]   PRECISION AND ACCURACY OF MEASUREMENTS OF WHOLE-BODY BONE-MINERAL - COMPARISONS BETWEEN HOLOGIC, LUNAR AND NORLAND DUAL-ENERGY X-RAY A ABSORPTIOMETERS [J].
TOTHILL, P ;
AVENELL, A ;
REID, DM .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (804) :1210-1217