PRECISION AND ACCURACY OF MEASUREMENTS OF WHOLE-BODY BONE-MINERAL - COMPARISONS BETWEEN HOLOGIC, LUNAR AND NORLAND DUAL-ENERGY X-RAY A ABSORPTIOMETERS

被引:106
作者
TOTHILL, P
AVENELL, A
REID, DM
机构
[1] ROWETT RES INST,ABERDEEN AB2 9SB,SCOTLAND
[2] CITY HOSP,DEPT RHEUMATOL,ABERDEEN AB9 8AU,SCOTLAND
关键词
D O I
10.1259/0007-1285-67-804-1210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Measurements of whole-body bone mineral made by Hologic, Lunar and Norland dual-energy X-ray absorptiometers have been compared. It was found that in each case the results were changed by new software protocols introduced by the manufacturers during the course of the study. With a moderately anthropomorphic model, the later software corrected some anomalies of regional bone mineral content (BMC) observed earlier. There was some slight dependence of total BMC on thickness and fat proportion and up to 15% difference between instruments. Measurements on volunteers showed good precision, but there were differences between instruments made by different manufacturers. There were high correlations, but the slopes of regression lines suggested differences of calibration of up to 8%; the standard errors of the estimates were 110 to 190 g, with maximum deviations from regression of 17%. There were regional disparities in BMC, particularly in the trunk, which arise (in part at least) from the imposition of a higher bone threshold by Hologic. From the pattern of results it was concluded that different assumptions were made by the manufacturers, particularly concerning the fat distribution model, which preclude the interchangeability of results from different instruments.
引用
收藏
页码:1210 / 1217
页数:8
相关论文
共 15 条
  • [1] DUAL ENERGY X-RAY ABSORPTIOMETRY - THE EFFECTS OF BEAM HARDENING ON BONE-DENSITY MEASUREMENTS
    BLAKE, GM
    MCKEENEY, DB
    CHHAYA, SC
    RYAN, PJ
    FOGELMAN, I
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 459 - 465
  • [2] TRIPLE PHOTON-ABSORPTIOMETRY CANNOT CORRECT FOR FAT INHOMOGENEITIES IN LUMBAR SPINE BONE-MINERAL MEASUREMENTS
    FARRELL, TJ
    WEBBER, CE
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (01): : 77 - 84
  • [3] TOTAL-BODY STUDIES IN NORMAL BRITISH WOMEN USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    HERD, RJM
    BLAKE, GM
    PARKER, JC
    RYAN, PJ
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784) : 303 - 308
  • [4] DUAL-PHOTON ABSORPTIOMETRY - COMPARISON OF BONE-MINERAL AND SOFT-TISSUE MASS MEASUREMENTS INVIVO WITH ESTABLISHED METHODS
    HEYMSFIELD, SB
    WANG, J
    HESHKA, S
    KEHAYIAS, JJ
    PIERSON, RN
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (06) : 1283 - 1289
  • [5] JONSON R, 1988, ACTA RADIOL, V29, P461
  • [6] THEORETICAL AND EXPERIMENTAL LIMITS OF TRIPLE PHOTON ENERGY ABSORPTIOMETRY IN THE MEASUREMENT OF BONE-MINERAL
    KOTZKI, PO
    MARIANOGOULART, D
    ROSSI, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (04) : 429 - 437
  • [7] KRISHNAN SS, 1993, HUMAN BODY COMPOSITI, P329
  • [8] LASKEY MA, 1992, EUR J CLIN NUTR, V46, P39
  • [9] MAZESS RB, 1981, CALCIFIED TISSUE INT, V33, P361
  • [10] MAZESS RB, 1992, BONE, V13, P280