Assessment of Myocardial Perfusion during Adenosine Stress Using Real Time Three-Dimensional and Two-Dimensional Myocardial Contrast Echocardiography: Comparison with Single-Photon Emission Computed Tomography

被引:17
作者
Abdelmoneim, Sahar S. [1 ,2 ]
Bernier, Mathieu [1 ]
Dhoble, Abhijeet [1 ]
Moir, Stuart [1 ]
Hagen, Mary E. [1 ]
Ness, Sue Ann C. [1 ]
Abdel-Kader, Samir S. [2 ]
Pellikka, Patricia A. [1 ]
Mulvagh, Sharon L. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Assiut Univ, Dept Cardiovasc Med, Assiut, Egypt
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2010年 / 27卷 / 04期
关键词
contrast echocardiography; coronary artery disease; single-photon emission computed tomography; 3-dimensional echocardiography; CORONARY-ARTERY-DISEASE; DIAGNOSTIC-ACCURACY; CONTINUOUS-INFUSION;
D O I
10.1111/j.1540-8175.2009.01026.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To evaluate diagnostic accuracy of adenosine two-dimensional and three-dimensional myocardial contrast echocardiography (2D- and 3D-MCE) compared with single-photon emission computed tomography (SPECT) for assessing myocardial perfusion. Methods: From January through August 2007, patients with known or suspected CAD who were referred for SPECT underwent simultaneous adenosine 2D-MCE and 3D-MCE (live and full volume [FV]). Perfusion and wall motion in 17 segments in the left anterior descending, left circumflex, and right coronary artery territories were analyzed. Results: We studied 30 patients: mean (SD) age, 72.6 (8.2) years; 19 (63%) men. Perfusion by SPECT was abnormal in 13 patients (43%). When comparing MCE with SPECT, sensitivity was comparable for 2D-MCE, 92%; live 3D-MCE, 91%; and FV 3D-MCE, 90%. Specificity was comparable for 2D-MCE, 75%; live 3D-MCE, 69%; and FV 3D-MCE, 79%. Agreement between live 3D-MCE and 2D-MCE was 92% (kappa[SE], 0.83 [0.17]) and between FV 3D-MCE and 2D-MCE, 88% (kappa[SE], 0.76 [0.13]). For eight patients in whom SPECT showed reversible defects, live 3D-MCE correctly identified defects in seven (88%), whereas FV 3D-MCE correctly identified them in five (63%) (P = 0.57). Conclusion: Myocardial perfusion assessment is feasible by 3D-MCE with the advantage of rapid, facile acquisition and offline image manipulation. (Echocardiography 2010;27:421-429).
引用
收藏
页码:421 / 429
页数:9
相关论文
共 19 条
[11]   Myocardial perfusion by contrast echocardiography: diagnosis of coronary artery disease using contrast-enhanced stress echocardiography and assessment of coronary anatomy and flow reserve [J].
Mulvagh, SL .
CORONARY ARTERY DISEASE, 2000, 11 (03) :243-251
[12]  
Nanda Navin C, 2006, J Cardiol, V48, P291
[13]   Real-time perfusion imaging: A new echocardiographic technique for simultaneous evaluation of myocardial perfusion and contraction [J].
Sieswerda, GT ;
Yang, L ;
Boo, MBD ;
Kamp, O .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2003, 20 (06) :545-555
[14]   Interrupted infusion of echocardiographic contrast as a basis for accurate measurement of myocardial perfusion: Ex vivo validation and analysis procedures [J].
Toledo, E ;
Collins, KA ;
Williams, U ;
Lammertin, G ;
Bolotin, G ;
Raman, J ;
Lang, RM ;
Mor-Avi, V .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1312-1320
[15]   Imaging and quantification of myocardial perfusion using real-time three-dimensional echocardiography [J].
Toledo, E ;
Lang, RM ;
Collins, KA ;
Lammertin, G ;
Williams, U ;
Weinert, L ;
Bolotin, G ;
Coon, PD ;
Raman, J ;
Jacobs, LD ;
Mor-Avi, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (01) :146-154
[16]   Diagnostic accuracy and prognostic value of dobutamine stress myocardial contrast echocardiography in patients with suspected acute coronary syndromes [J].
Tsutsui, JM ;
Xie, F ;
O'Leary, EL ;
Elhendy, A ;
Anderson, JR ;
McGrain, AC ;
Porter, TR .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (06) :487-495
[17]   Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion? [J].
Wei, K ;
Jayaweera, AR ;
Firoozan, S ;
Linka, A ;
Skyba, DM ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (01) :252-260
[18]   Detection of coronary artery disease with a continuous infusion of definity ultrasound contrast during adenosine stress real time perfusion echocardiography [J].
Xie, Feng ;
Hankins, Jordan ;
Mahrous, Heidi A. ;
Porter, Thomas R. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10) :1044-1050
[19]   Role of biplane and biplane echocardiographically guided 3-dimensional echocardiography during dobutamine stress echocardiography [J].
Yang, Hyun Suk ;
Pellikka, Patricia A. ;
McCully, Robert B. ;
Oh, Jae K. ;
Kukuzke, Joyce A. ;
Khandheria, Bijoy K. ;
Chandrasekaran, Krishnaswamy .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (09) :1136-1143