A mediated polyphenol oxidase biosensor immobilized by electropolymerization of 1,2-diamino benzene

被引:21
作者
Akyilmaz, Erol [1 ]
Kozgus, Ozge [1 ]
Turkmen, Hayati [2 ]
Cetinkaya, Bekir [2 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
[2] Ege Univ, Fac Sci, Dept Chem, TR-35100 Bornova, Turkey
关键词
Polyphenole oxidase; Biosensor; Catechol; Mediator; 1,2-diamino benzene; AMPEROMETRIC BIOSENSORS; ELECTRON-TRANSFER; GOLD NANOPARTICLES; ENZYME ELECTRODE; GLUCOSE-OXIDASE; TYROSINASE; FILMS; PEROXIDASE; COMPLEXES; COMPOSITE;
D O I
10.1016/j.bioelechem.2009.09.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A biosensor based on a partially purified polyphenol oxidase (PPO) enzyme was developed by using electropolymerization of [(2,2'-bipyridine)(chloro)(p-cymene)rutenium(II)]chloride] mediator complex and 1,2-diamino benzene (DAB) on a screen printing Pt electrode (1 mm diameter). The electropolymerization was carried out at +0.7 V for 45 min in phosphate buffer (50 mM, pH 7.0) which contained 14.0 U/10 mL polyphenole oxidase, 200 mM DAB and 2.5 mM Ru-mediator complex solutions. Measurement is based on the detection of the oxidation current of the Ru-mediator complex that related to the enzymatic reaction catalyzed by PPO at +0.65 V. The phosphate buffer (50 mM, pH 7.0 containing 0.1 M KCl) and 30 degrees C were established as being the optimum working conditions. Under the optimum experimental conditions a linear calibration curve was obtained between 5 and 100 mu M catechol concentration. The detection limit of the biosensor is 2.385 mu M. In the characterization studies of the biosensor some parameters such as effect of Ru-mediator types on the biosensor response, substrate specificity, reproducibility and storage stability were studied. From the experiments, the average value (x), standard deviation (SD) and coefficient of variation (CV%) were found to be 48.75 mu M, 1.56 mu M, and 3.2% respectively for 50 mu M catechol standard. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 37 条
  • [1] Investigation of metal activation of a partially purified polyphenol oxidase enzyme electrode
    Akyilmaz, Erol
    Baysal, Senay Hamarat
    Dinckaya, Erhan
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (10-11) : 755 - 761
  • [2] Development of a high analytical performance-tyrosinase biosensor based on a composite graphite -: Teflon electrode modified with gold nanoparticles
    Carralero, V.
    Mena, M. L.
    Gonzalez-Cortes, A.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 22 (05) : 730 - 736
  • [3] Application of electrosynthesized poly(aniline-co-p-aminophenol) as a catechol sensor
    Chen, Chuanxiang
    Sun, Cheng
    Gao, Yuhua
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (09) : 2575 - 2580
  • [4] Amperometric tyrosinase biosensor based on Fe3O4 nanoparticles-coated carbon nanotubes nanocomposite for rapid detection of coliforms
    Cheng, Yuxiao
    Liu, Yajun
    Huang, Jingjing
    Li, Kang
    Xian, Yuezhong
    Zhang, Wen
    Jin, Litong
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (09) : 2588 - 2594
  • [5] Physicochemical characterization of the layer-by-layer self-assembly of polyphenol oxidase and chitosan on glassy carbon electrode
    Coche-Guérente, L
    Desbrières, J
    Fatisson, J
    Labbé, P
    Rodriguez, MC
    Rivas, G
    [J]. ELECTROCHIMICA ACTA, 2005, 50 (14) : 2865 - 2877
  • [6] Mediated electrochemical detection of catechol by tyrosinase-based poly(dicarbazole) electrodes
    Cosnier, S
    Szunerits, S
    Marks, RS
    Lellouche, JP
    Perie, K
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 50 (01): : 65 - 77
  • [7] Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    Cosnier, S
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) : 443 - 456
  • [8] Organic phase PPO biosensor based on hydrophilic films of electropolymerized polypyrrole
    Cristea, C
    Mousty, C
    Cosnier, S
    Popescu, IC
    [J]. ELECTROCHIMICA ACTA, 2005, 50 (18) : 3713 - 3718
  • [9] A new interference-free lysine biosensor using a non-conducting polymer film
    Curulli, A
    Kelly, S
    O'Sullivan, C
    Guilbault, GG
    Palleschi, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (12) : 1245 - 1250
  • [10] Flow-injection determination of catechol with a new tyrosinase/DNA biosensor
    Dantoni, P
    Serrano, SHP
    Brett, AMO
    Gutz, IGR
    [J]. ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) : 137 - 145