Lung function measurement in general practice. General practice measurements compared with laboratory measurements during the DIMCA trial

被引:5
作者
den Otter, JJ [1 ]
de Bruyn-Schmidt, MA [1 ]
Wolters, MJ [1 ]
van Schayck, CP [1 ]
Folgering, HTM [1 ]
van den Hoogen, HJM [1 ]
van Weel, C [1 ]
机构
[1] Univ Nijmegen M229, Dept Gen Practice & Social Med, NL-6500 HB Nijmegen, Netherlands
关键词
decline; general practice; lung function measurement;
D O I
10.1093/fampra/17.4.314
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background. Lung function measurement in the general practice setting (GPS) is of growing importance. Objective. The aim of this study was to compare results from a lung function laboratory (LFL) with those in a GPS. Methods. Comparisons were made for decline calculated from GPS and LFL measurements and intra-individual paired measurements. Test characteristics of the spirometer used in the GPS were also assessed. Results. The mean decline in lung function was: -0.037 l/year [95% confidence interval (CI) -0.202 to 0.129] from LFL data and -0.027 l/year (95% CI -0.242 to 0.188) from GPS data. The mean intra-individual difference was -0.0025 l (95% CI -0.493 to 0.488 l). The test characteristics of the spirometer used in GPS did not meet all of the American Thoracic Society guidelines; in particular, the random error was too large. The difference in assessments between measurement in LFL and GPS were such that misclassification might occur if slopes were calculated. Conclusions. Repeated measurement in this study showed that GPS measurements are not interchangeable with LFL measurements. Therefore, one has to be cautious when interchanging lung function data from an LFL and a GPS.
引用
收藏
页码:314 / 316
页数:3
相关论文
共 13 条
[2]  
[Anonymous], 1987, Am Rev Respir Dis, V136, P1285
[3]  
BECKLAKE MR, 1993, OCCUP MED, V8, P241
[4]  
denOtter JJ, 1997, BRIT J GEN PRACT, V47, P41
[5]   Long term performance of a hand held spirometer [J].
Dirksen, A ;
Madsen, F ;
Pedersen, OF ;
Vedel, AM ;
KokJensen, A .
THORAX, 1996, 51 (10) :973-976
[6]  
Geijer R. M. M., 1997, HUISARTS WET, P430
[7]   Routine pulmonary function tests in young adolescents with asthma in general practice [J].
Hewson, PH ;
Tippett, EA ;
Jones, DM ;
Maddern, JP ;
Higgs, P .
MEDICAL JOURNAL OF AUSTRALIA, 1996, 165 (09) :469-472
[8]  
HULSCHER M, 1998, THESIS U NIJMEGEN, P1
[9]   Peak-expiratory-flow meters and asthma self-management [J].
Legge, JS .
LANCET, 1996, 347 (9017) :1709-1710
[10]   PERFORMANCE EVALUATION OF CONTEMPORARY SPIROMETERS [J].
NELSON, SB ;
GARDNER, RM ;
CRAPO, RO ;
JENSEN, RL .
CHEST, 1990, 97 (02) :288-297