Screening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography

被引:22
作者
Lim-Bon-Siong, R
Williams, JM
Samapunphong, S
Chuck, RS
Pepose, JS
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Pathol, St Louis, MO 63110 USA
[3] Univ Massachusetts, Med Ctr, Dept Ophthalmol, Worcester, MA USA
关键词
D O I
10.1001/archopht.116.5.617
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: In contrast to incisional keratotomy, corneas that have undergone photorefractive keratectomy may be difficult to detect by inspection with slitlamp biomicroscopy alone. Eye bank corneas that have undergone high myopic refractive surgical correction could potentially result in substantial postoperative hyperopic correction if used as donor tissue for corneal transplantation. Surface irregularities or displacement of the treated optical zone within the graft in relation to the entrance pupil of the recipient could result in significant induced astigmatism and distortion. This study examines computerized videokeratographic screening of eye bank globes as a strategy for detecting myopic photorefractive keratectomy. Methods: Preoperative and postoperative corneal topographic maps of freshly enucleated human and rabbit eyes that have undergone myopic photorefractive keratectomy with an excimer laser were placed in a globe-fixating device and analyzed using a vertically oriented videokeratoscope. The same system was applied in an actual eye bank setting, and potentially transplantable globes from donors without a history of corneal surgery were analyzed. Results: Computerized videokeratography using a vertically mounted system reliably detected photorefractive keratectomy in 12 of 12 human eye bank corneas treated by excimer photorefractive keratectomy in a range between -1.5 to -6.0 diopters. This method also detected similar changes on lased rabbit corneas enucleated 6 weeks after excimer surgery. Data processed with the tangential mode yielded a "bull's-eye" topography pattern reflecting central corneal flattening that was more sensitive in detecting myopic corrections than the conventional axial formula-based color maps. False-positive results were not detected in 96 cadaver globes sequentially screened in the eye bank. Conclusions: Computerized videokeratography represents a feasible method to screen donor globes for myopic photorefractive keratectomy as shown by the in vitro and rabbit models. However, only whole globes and not corneoscleral sections are amenable to processing with this technique. Tangential maps provided greater sensitivity in detecting low myopic corrections than the axial formula-based color maps.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 17 条
[1]  
BELMONT SC, 1994, J REFRACT CORNEAL S, V10, P658
[2]   COMPUTER-ASSISTED VIDEOKERATOGRAPHY OF CORNEAL TOPOGRAPHY AFTER RADIAL KERATOTOMY [J].
BOGAN, SJ ;
MALONEY, RK ;
DREWS, CD ;
WARING, GO .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (06) :834-841
[3]   CLASSIFICATION OF NORMAL CORNEAL TOPOGRAPHY BASED ON COMPUTER-ASSISTED VIDEOKERATOGRAPHY [J].
BOGAN, SJ ;
WARING, GO ;
IBRAHIM, O ;
DREWS, C ;
CURTIS, L .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :945-949
[4]   ASSESSMENT OF THE POWER AND HEIGHT OF RADIAL ASPHERES REPORTED BY A COMPUTER-ASSISTED KERATOSCOPE [J].
COHEN, KL ;
TRIPOLI, NK ;
HOLMGREN, DE ;
COGGINS, JM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (06) :723-732
[5]   THE TOPOGRAPHY OF NORMAL CORNEAS [J].
DINGELDEIN, SA ;
KLYCE, SD .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (04) :512-518
[6]   REPRODUCIBILITY OF NORMAL CORNEAL POWER MEASUREMENTS WITH A KERATOMETER, PHOTOKERATOSCOPE, AND VIDEO IMAGING-SYSTEM [J].
HANNUSH, SB ;
CRAWFORD, SL ;
WARING, GO ;
GEMMILL, MC ;
LYNN, MJ ;
NIZAM, A .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (04) :539-544
[7]   CORNEAL TOPOGRAPHY OF PHASE-III EXCIMER-LASER PHOTOREFRACTIVE KERATECTOMY - CHARACTERIZATION AND CLINICAL EFFECTS [J].
HERSH, PS ;
SCHWARTZGOLDSTEIN, BH ;
DURRIE, D ;
CAVANAUGH, T ;
HUNKELER, J ;
MICHELSON, M ;
OWEN, J ;
GORDON, M ;
STEINERT, R ;
PULIAFITO, C ;
RAIZMAN, M ;
PEPOSE, J .
OPHTHALMOLOGY, 1995, 102 (06) :963-978
[8]  
MCDONNELL PJ, 1989, OPHTHALMOLOGY, V96, P45
[9]  
PALLIKARIS IG, 1994, J REFRACT CORNEAL S, V10, P498
[10]   THE EFFECT OF ARTIFICIAL TEARS ON COMPUTER-ASSISTED CORNEAL TOPOGRAPHY IN NORMAL EYES AND AFTER PENETRATING KERATOPLASTY [J].
PAVLOPOULOS, GP ;
HORN, J ;
FELDMAN, ST .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (06) :712-722