Label-free electrochemical impedance spectroscopy biosensor for the determination of human immunoglobulin G

被引:50
作者
Qi, Honglan [1 ]
Wang, Chen [1 ]
Cheng, Ning [1 ]
机构
[1] Shaanxi Normal Univ, Key Lab Analyt Chem Life Sci Shaanxi Prov, Sch Chem & Mat Sci, Xian 710062, Peoples R China
关键词
Electrochemical impedance spectroscopy; Biosensor; Protein A; Human immunoglobulin G; FLOW-INJECTION IMMUNOASSAY; PROTEIN-A; ANTIBODY IMMOBILIZATION; PIEZOELECTRIC BIOSENSOR; IMMUNOSENSOR ASSAY; GOLD; IGG; FILMS; APTASENSOR; MONOLAYERS;
D O I
10.1007/s00604-010-0382-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive biosensor was developed for the determination of human immunoglobulin G (IgG). Protein A was employed as molecular receptor and electrochemical impedance spectroscopy (EIS) was used as detection technique. The biosensor was obtained by self-assembling protein A on a gold electrode. The surface morphology of the self-assembled layer before and after interaction with IgG was studied by atomic force microscopy. Protein A bound specifically to the Fc portion of IgG, and this caused a change in the resistance of the interfacial electron transfer when using a ferrocyanide redox couple as a probe. The increase of the resistance of the electron transfer was linearly related to the concentration of IgG in the range from 10 ng.mL(-1) to 1.0 mu g.mL(-1), with a detection limit of 5 ng.mL(-1). The work demonstrates that protein A is a versatile matrix for the immobilization of antibodies.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 40 条
  • [1] Effectiveness of protein A for antibody immobilization for a fiber optic biosensor
    Anderson, GP
    Jacoby, MA
    Ligler, FS
    King, KD
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (04) : 329 - 336
  • [2] Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol
    Barton, Andrew C.
    Davis, Frank
    Higson, Seamus P. J.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (16) : 6198 - 6205
  • [3] Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications
    Barton, Andrew C.
    Collyer, Stuart D.
    Davis, Frank
    Garifallou, Goulielmos-Zois
    Tsekenis, Georgios
    Tully, Elizabeth
    O'Kennedy, Richard
    Gibson, Tim
    Millner, Paul A.
    Higson, Seamus P. J.
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) : 1090 - 1095
  • [4] Challenges of Electrochemical Impedance Spectroscopy in Protein Biosensing
    Bogomolova, A.
    Komarova, E.
    Reber, K.
    Gerasimov, T.
    Yavuz, O.
    Bhatt, S.
    Aldissi, M.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 3944 - 3949
  • [5] ANALYTICAL POTENTIAL OF PROTEIN-A FOR AFFINITY-CHROMATOGRAPHY OF POLYCLONAL AND MONOCLONAL-ANTIBODIES
    COMPTON, BJ
    LEWIS, M
    WHIGHAM, F
    GERALD, JS
    COUNTRYMAN, GE
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (13) : 1314 - 1317
  • [6] Biosensors based on electropolymerized films: new trends
    Cosnier, S
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) : 507 - 520
  • [7] SYNTHESIS OF PROTEIN-DOPED SOL-GEL SIO2 THIN-FILMS - EVIDENCE FOR ROTATIONAL MOBILITY OF ENCAPSULATED CYTOCHROME-C
    DAVE, BC
    SOYEZ, H
    MILLER, JM
    DUNN, B
    VALENTINE, JS
    ZINK, JI
    [J]. CHEMISTRY OF MATERIALS, 1995, 7 (08) : 1431 - 1434
  • [8] CONTINUOUS LIQUID-PHASE PIEZOELECTRIC BIOSENSOR FOR KINETIC IMMUNOASSAYS
    DAVIS, KA
    LEARY, TR
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (11) : 1227 - 1230
  • [9] RAPID HETEROGENEOUS COMPETITIVE ELECTROCHEMICAL IMMUNOASSAY FOR IGG IN THE PICOMOLE RANGE
    DEALWIS, U
    WILSON, GS
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2786 - 2789
  • [10] Impedimetric Aptasensor with Femtomolar Sensitivity Based on the Enlargement of Surface-Charged Gold Nanoparticles
    Deng, Chunyan
    Chen, Jinhua
    Nie, Zhou
    Wang, Mengdong
    Chu, Xiaochen
    Chen, Xiaoli
    Xiao, Xilin
    Lei, Chunyang
    Yao, Shouzhuo
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (02) : 739 - 745