Positive and negative electrospray LC-MS-MS methods for quantitation of the antiparasitic endectocide drugs, abamectin, doramectin, emamectin, eprinomectin, ivermectin, moxidectin and selamectin in milk

被引:69
作者
Durden, David A. [1 ]
机构
[1] Canadian Food Inspect Agcy, Calgary, AB T2L 2L1, Canada
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 850卷 / 1-2期
关键词
avermectin; endectocide; milk; LC-MS-MS; electrospray ionization; liquid chromatography; tandem mass spectrometry; residue analysis; abamectin; doramectin; emamectin; eprinomectin; ivermectin; moxidectin; selamectin;
D O I
10.1016/j.jchromb.2006.11.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Avermectin endectocides are used for the treatment of cattle against a variety of nematode and arthropod parasites, and consequently may appear in milk after normal or off-label use. The compounds abamectin, doramectin, and ivermectin, contain only C, H and 0 and may be expected to be detected by LC-MS in negative ion mode. The others contain nitrogen in addition and would be expected to be preferentially ionized in positive mode. The use of positive ion and negative ion methods with electrospray LC-MS-MS were compared. Using negative ion the compounds abarnectin, doramectin, ivermectin, emarnectin, eprinomectin, and moxidectin gave a curvilinear response and were quantified in raw milk by LC-MS-MS with a triethylamine-acetonitrile buffer over the concentration range 1-60ppb (mu g/kg) using selarnectin as the internal standard. The limits of detection (LOD) were between 0.19 ppb (doramectin) and 0.38 ppb (emamectin). The compounds gave maximum sensitivity with positive ionisation from a formic acid-ammonium formate-acetonitrile buffer and were detected in milk (LC-MS-MS) also with a curvilinear response over the range 0.5-60 ppb. Although the positive ion signals were larger, with somewhat lower limits of detection (LOD between 0.06 ppb (doramectin) and 0.32 ppb (moxidectin) the negative ion procedure gave a more linear response and more consistent results. Comparison of spiked samples in the range 2-50 ppb showed a high degree of correlation between the two methods. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 146
页数:13
相关论文
共 26 条
[1]  
Ali MS, 2000, J AOAC INT, V83, P39
[2]  
Ali MS, 2000, J AOAC INT, V83, P31
[3]   Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods [J].
Almeida, AM ;
Castel-Branco, MM ;
Falcao, AC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :215-222
[4]   Estimating provisional acceptable residues for extralabel drug use in livestock [J].
Baynes, RE ;
Martin-Jiménez, T ;
Craigmill, AL ;
Riviere, JE .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 1999, 29 (03) :287-299
[5]   Determination of ivermectin B1a in animal plasma by liquid chromatography combined with electrospray ionization mass spectrometry [J].
Croubels, S ;
De Baere, S ;
Cherlet, M ;
De Backer, P .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (08) :840-847
[6]   Development and optimisation of an improved derivatisation procedure for the determination of avermectins and milbemycins in bovine liver [J].
Danaher, M ;
O'Keeffe, M ;
Glennon, JD ;
Howells, L .
ANALYST, 2001, 126 (05) :576-580
[7]   A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[8]   DORAMECTIN - A POTENT NOVEL ENDECTOCIDE [J].
GOUDIE, AC ;
EVANS, NA ;
GRATION, KAF ;
BISHOP, BF ;
GIBSON, SP ;
HOLDOM, KS ;
KAYE, B ;
WICKS, SR ;
LEWIS, D ;
WEATHERLEY, AJ ;
BRUCE, CI ;
HERBERT, A ;
SEYMOUR, DJ .
VETERINARY PARASITOLOGY, 1993, 49 (01) :5-15
[9]   PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH NEGATIVE-ION CHEMICAL IONIZATION FOR THE CONFIRMATION OF IVERMECTIN RESIDUE IN BOVINE-MILK AND LIVER [J].
HELLER, DN ;
SCHENCK, FJ .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (03) :184-193
[10]   Multi-residue analysis of avermectins and moxidectin by ion-trap LC-MSn [J].
Howells, L ;
Sauer, MJ .
ANALYST, 2001, 126 (02) :155-160