摘要
The evaporation process of liquids from sub-nanoliter wells is studied using both optical microscopy and electrical impedance measurement utilizing integrated electrodes. The wells are manufactured on silicon wafers using conventional photolithography and etching techniques. The volumes of the wells vary from 15 to 540 pl. The evaporation rate of glycol from wells of various sizes is determined to vary from 0.2 (15-pl well) to 1.7 pl/s (540-pl well). Measurements show that the evaporation rate of glycol depends linearly on the weil width. not on the well surface area. The impedance measurement between two integrated electrodes located in the well is an accurate method for monitoring the liquid evaporation in sub-nanoliter wells, and can be applied in automated high-speed screening (HSS) systems. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:384 / 389
页数:6
相关论文
共 14 条
[1]   Electrochemical analysis in picoliter microvials [J].
Clark, RA ;
Hietpas, PB ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :259-263
[2]   Detecting biomolecules in picoliter vials using aequorin bioluminescence [J].
Crofcheck, CL ;
Grosvenor, AL ;
Anderson, KW ;
Lumpp, JK ;
Scott, DL ;
Daunert, S .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4768-4772
[3]   Capillary flow as the cause of ring stains from dried liquid drops [J].
Deegan, RD ;
Bakajin, O ;
Dupont, TF ;
Huber, G ;
Nagel, SR ;
Witten, TA .
NATURE, 1997, 389 (6653) :827-829
[4]   Calibration of micropipets using the bioluminescent protein aequorin [J].
Grosvenor, AL ;
Crofcheck, CL ;
Anderson, KW ;
Scott, DL ;
Daunert, S .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :3115-3118
[5]  
HARRISON DJ, 1998, P MICR 98 WORKSH BAN
[6]   EVAPORATION RATE OF WATER IN A VESSEL [J].
HISATAKE, K ;
TANAKA, S ;
AIZAWA, Y .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (11) :7395-7401
[7]   High-resolution liquid volume detection in sub-nanoliter reactors [J].
Hjelt, KT ;
van den Doel, R ;
Lubking, W ;
Vellekoop, MJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) :61-66
[8]  
HJELT KT, 1999, P TRANSD 99 SEND JAP, P748
[9]   Micromechanical compartments for biotechnological applications: fabrication and investigation of liquid evaporation [J].
Mayer, G ;
Kohler, JM .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 60 (1-3) :202-207
[10]   Micro-injection of β-D-glucose standards and Amplex Red reagent on micro-arrays [J].
Moerman, R ;
van den Doel, LR ;
Picioreanu, S ;
Frank, J ;
Marijnissen, JCM ;
van Dedem, G ;
Hjelt, KH ;
Vellekoop, MJ ;
Sarro, PM ;
Young, IT .
MICRO- AND NANOFABRICATED STRUCTURES AND DEVICES FOR BIOMEDICAL ENVIRONMENTAL APPLICATIONS II, 1999, 3606 :119-128