Tapered cementless femoral fixation provides a reliable option for routine primary total hip arthroplasty (THA). The Use of hydroxyapatite (HA)-coated stems is increasing as a result of mounting evidence that HA may improve the reliability of hone osseointegration and improve overall THA outcomes. These trends arc based on a growing body of literature that Supports both the theoretical and clinical rationale of this approach. There is solid clinical evidence that the combination of tapered geometry with an HA coating increases the likelihood of reliable femoral fixation. A comprehensive review of this literature evaluating the clinical use of cementless femoral components that use an HA coating is presented, and reveals that HA-coated sterns have significantly improved proximal femoral fixation with less stress shielding and superior osseous remodeling. Although these advantages have not been shown to significantly increase long-term durability, there is sufficient data to support the routine use of HA-coated, tapered cementless femoral sterns in THA.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 18 条
[1]
Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old - A concise follow-up of a previous report [J].
Capello, WN ;
D'Antonio, JA ;
Feinberg, JR ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :885-889
[2]
A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem [J].
Coathup, MJ ;
Blunn, GW ;
Flynn, N ;
Williams, C ;
Thomas, NP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :118-123
[3]
Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation [J].
Dorr, LD ;
Wan, ZN ;
Song, M ;
Ranawat, A .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :729-736
[4]
HELLMAN EJ, 1999, CLIN ORTHOP RELAT R, V364, P164
[5]
Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating [J].
Kim, YH ;
Kim, JS ;
Oh, SH ;
Kim, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09) :1682-1688
[6]
Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty [J].
Mallory, TH ;
Lombardi, AV ;
Leith, JR ;
Fujita, H ;
Hartman, JF ;
Capps, SG ;
Kefauver, CA ;
Adams, JB ;
Vorys, GC .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :49-54
[7]
The results at nine to twelve years of the use of a hydroxyapatite-coated femoral stem [J].
McNally, SA ;
Shepperd, JAN ;
Mann, CV ;
Walczak, JP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03) :378-382
[8]
Minimum ten-year follow-up of a straight-stemmed, plasma-sprayed, titanium-alloy, uncemented femoral component in primary total hip arthroplasty [J].
Meding, JB ;
Keating, EM ;
Ritter, MA ;
Faris, PM ;
Berend, ME .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :92-97
[9]
Prospective matched-pair analysis of hydroxyapatite- coated and uncoated femoral stems in total hip arthroplasty - A concise follow-up of a previous report [J].
Parvizi, J ;
Sharkey, PF ;
Hozack, WJ ;
Orzoco, F ;
Bissett, GA ;
Rothman, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04) :783-786
[10]
Hydroxyapatite - Catalyst or conjuror? [J].
Rasquinha, VJ ;
Ranawat, CS ;
Mauriello, AJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :113-117