Performance of quantitative analyses by liquid chromatography-electrospray ionisation tandem mass spectrometry: from external calibration to isotopomer-based exact matching

被引:20
作者
Delatour, T [1 ]
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
关键词
mass spectrometry; external calibration; internal calibration; isotope dilution; exact matching; internal standard; matrix effect;
D O I
10.1007/s00216-004-2750-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a versatile coupling system which combines both selectivity and sensitivity and certainty. Hence, it is generally considered as the most reliable technique to quantify chemical compounds in complex matrices. In the present paper, we evaluate the performance of LC-MS/MS methods for the quantification of 3-nitrotyrosine in human urine in order to point out its dependence on the design of the quantification method, and emphasize the role of matrix effects in the performance. We compare external and internal calibrations, isotope dilution and isotopomer-based exact matching. The role of both sample preparation and multiple transitions monitoring is particularly addressed.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 25 条
[1]   LC-MS/MS detection of peroxynitrite-derived 3-nitrotyrosine in rat microvessels [J].
Althaus, JS ;
Schmidt, KR ;
Fountain, ST ;
Tseng, MT ;
Carroll, RT ;
Galatsis, P ;
Hall, ED .
FREE RADICAL BIOLOGY AND MEDICINE, 2000, 29 (11) :1085-1095
[2]   Effect of liquid chromatography separation of complex matrices on liquid chromatography-tandem mass spectrometry signal suppression [J].
Choi, BK ;
Hercules, DM ;
Gusev, AI .
JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) :337-342
[3]   LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices [J].
Choi, BK ;
Hercules, DM ;
Gusev, AI .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (3-4) :370-377
[4]   Quantitative analysis of amoxycillin and its major metabolites in animal tissues by liquid chromatography combined with electrospray ionization tandem mass spectrometry [J].
De Baere, S ;
Cherlet, M ;
Baert, K ;
De Backer, P .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1393-1401
[5]   3-nitrotyrosine butyl ester: A novel derivative to assess tyrosine nitration in rat plasma by liquid chromatography-tandem mass spectrometry detection [J].
Delatour, T ;
Guy, PA ;
Stadler, RH ;
Turesky, RJ .
ANALYTICAL BIOCHEMISTRY, 2002, 302 (01) :10-18
[6]   Simultaneous determination of 3-nitrotyrosine and tyrosine in plasma proteins of rats and assessment of artifactual tyrosine nitration [J].
Delatour, T ;
Richoz, J ;
Vouros, P ;
Turesky, RJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02) :189-199
[7]   Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) :347-357
[8]   INVESTIGATIONS OF THE ELECTROSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :957-967
[9]  
Kaur H, 1998, J NEUROCHEM, V70, P2220
[10]   Liquid chromatography-electrospray tandem mass spectrometry of acidic monoamine metabolites [J].
Manini, P ;
Andreoli, R ;
Cavazzini, S ;
Bergamaschi, E ;
Mutti, A ;
Niessen, WNA .
JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (02) :423-431