Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data

被引:101
作者
Jiang, H [1 ]
Paganetti, H
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
GEANT4; Monte Carlo; CT;
D O I
10.1118/1.1796952
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The GEANT4 Monte Carlo code provides many powerful functions for conducting particle transport simulations with great reliability and flexibility. However, as a general purpose Monte Carlo code, not all the functions were specifically designed and fully optimized for applications in radiation therapy. One of the primary issues is the computational efficiency, which is especially critical when patient CT data have to be imported into the simulation model. In this paper we summarize the relevant aspects of the GEANT4 tracking and geometry algorithms and introduce our work on using the code to conduct dose calculations based on CT data. The emphasis is focused on modifications of the GEANT4 source code to meet the requirements for fast dose calculations. The major features include a quick voxel search algorithm, fast volume optimization, and the dynamic assignment of material density. These features are ready to be used for tracking the primary types of particles employed in radiation therapy such as photons, electrons, and heavy charged particles. Recalculation of a proton therapy treatment plan generated by a commercial treatment planning program for a paranasal sinus case is presented as an example. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:2811 / 2818
页数:8
相关论文
共 21 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
BRIESMEISTER JF, 2000, LA13079 LOS ALM NAT
[3]   Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics [J].
Carrier, JF ;
Archambault, L ;
Beaulieu, L ;
Roy, R .
MEDICAL PHYSICS, 2004, 31 (03) :484-492
[4]   Monte Carlo simulation of a dynamic MLC based on a multiple source model [J].
Fix, MK ;
Manser, P ;
Born, EJ ;
Mini, R ;
Rüegsegger, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3241-3257
[5]   Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy [J].
Fix, MK ;
Keller, H ;
Rüegsegger, P ;
Born, EJ .
MEDICAL PHYSICS, 2000, 27 (12) :2739-2747
[6]   A multiple source model for 6 MV photon beam dose calculations using Monte Carlo [J].
Fix, MK ;
Stampanoni, M ;
Manser, P ;
Born, EJ ;
Mini, R ;
Rüegsegger, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :1407-1427
[7]   A pencil beam algorithm for proton dose calculations [J].
Hong, L ;
Goitein, M ;
Bucciolini, M ;
Comiskey, R ;
Gottschalk, B ;
Rosenthal, S ;
Serago, C ;
Urie, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08) :1305-1330
[8]   Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :485-498
[9]  
Oelfke U, 2001, Med Dosim, V26, P113, DOI 10.1016/S0958-3947(01)00057-7
[10]   Four-dimensional Monte Carlo simulation of time-dependent geometries [J].
Paganetti, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06) :N75-N81