Quantitative analysis using Raman spectrometry

被引:354
作者
Pelletier, MJ [1 ]
机构
[1] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
关键词
D O I
10.1366/000370203321165133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of Raman spectroscopy as a tool for quantitative analysis is discussed. The high information content and good spectral resolution typical of Raman spectra allow simple analytical models to be accurate and robust. Spectral preprocessing, noise analysis and multivariate methods applied to more complex samples are also discussed.
引用
收藏
页码:20A / 42A
页数:23
相关论文
共 255 条
[111]   MEASUREMENT OF FLUID FILM THICKNESS ON CURVED SURFACES BY RAMAN-SPECTROSCOPY [J].
HUTCHINSON, EJ ;
SHU, D ;
LAPLANT, F ;
BENAMOTZ, D .
APPLIED SPECTROSCOPY, 1995, 49 (09) :1275-1278
[112]   USE OF RAMAN-SPECTROSCOPY FOR QUANTITATIVE-ANALYSIS OF IMPURITIES - SULFATE IN NANO3 [J].
IRISH, DE ;
RIDDELL, JD .
APPLIED SPECTROSCOPY, 1974, 28 (05) :481-482
[113]   APPLICATION OF RAMAN SPECTROSCOPY TO CHEMICAL ANALYSIS [J].
IRISH, DE ;
CHEN, H .
APPLIED SPECTROSCOPY, 1971, 25 (01) :1-&
[114]   FOURIER-TRANSFORM RAMAN-SPECTROSCOPY OF ELASTOMERS - AN OVERVIEW [J].
JACKSON, KDO ;
LOADMAN, MJR ;
JONES, CH ;
ELLIS, G .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1990, 46 (02) :217-226
[115]   QUANTITATIVE-ANALYSIS USING RAMAN METHODS [J].
JAWHARI, T ;
HENDRA, PJ ;
WILLIS, HA ;
JUDKINS, M .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1990, 46 (02) :161-170
[116]   Quantitative determination of unsaturation in photocured halogenated acrylates and methacrylates by FT-IR and Raman-spectroscopy and by thermal analysis [J].
Jöhnck, M ;
Müller, L ;
Neyer, A ;
Hofstraat, JW .
POLYMER, 1999, 40 (13) :3631-3639
[117]   Application of wavelet transform to extract the relevant component from spectral data for multivariate calibration [J].
JouanRimbaud, D ;
Walczak, B ;
Poppi, RJ ;
deNoord, OE ;
Massart, DL .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4317-4323
[118]   COMPARISON OF MULTIVARIATE METHODS BASED ON LATENT VECTORS AND METHODS BASED ON WAVELENGTH SELECTION FOR THE ANALYSIS OF NEAR-INFRARED SPECTROSCOPIC DATA [J].
JOUANRIMBAUD, D ;
WALCZAK, B ;
MASSART, DL ;
LAST, IR ;
PREBBLE, KA .
ANALYTICA CHIMICA ACTA, 1995, 304 (03) :285-295
[119]   A NEW APPROACH TO THE DETERMINATION OF FLUID PHASE-EQUILIBRIA - CONCENTRATION MEASUREMENTS BY RAMAN-SPECTROSCOPY [J].
KAISER, T ;
VOSSMERBAUMER, C ;
SCHWEIGER, G .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1992, 96 (08) :976-980
[120]   KINETICS OF DIACETYLENE POLYMERIZATION - AN FT-RAMAN STUDY [J].
KAMATH, M ;
KIM, WH ;
LI, L ;
KUMAR, J ;
TRIPATHY, S ;
BABU, KN ;
TALWAR, SS .
MACROMOLECULES, 1993, 26 (22) :5954-5958