Is adaptive treatment planning required for stereotactic radiotherapy of stage I non-small-cell lung cancer?

被引:45
作者
Haasbeek, Cornelis J. A. [1 ]
Lagerwaard, Frank J. [1 ]
Cuijpers, Johan P. [1 ]
Slotman, Ben J. [1 ]
Senan, Suresh [1 ]
机构
[1] VU Univ Med Ctr, Dept Radiat Oncol, NL-1081 HV Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 67卷 / 05期
关键词
four-dimensional computed tomographic scan; stereotactic radiotherapy; planning target volumes; adaptive radiotherapy; lung cancer;
D O I
10.1016/j.ijrobp.2006.11.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Changes in position or size of target volumes have been observed during radiotherapy for lung cancer. The need for adaptive treatment planning during stereotactic radiotherapy of Stage I tumors was retrospectively analyzed using repeat four-dimensional computed tomography (4DCT) scans. Methods and Materials: A planning study was performed for 60 tumors in 59 patients using 4DCT scans repeated after two or more treatment fractions. Planning target volumes (PTV) encompassed all tumor mobility, and dose distributions from the initial plan were projected onto PTVs derived from the repeat 4DCT. A dosimetric and volumetric analysis was performed. Results: The repeat 4DCT scans were performed at a mean of 6.6 days (range, 2-12 days) after the first fraction of stereotactic radiotherapy. In 25% of cases the repeat PTV was larger, but the difference exceeded 1 mL in 5 patients only. The mean 313 displacement between the center of mass of both PTVs was 2.0 nun. The initial 80% prescription isodose ensured a mean coverage of 98% of repeat PTVs, and this isodose fully encompassed the repeat internal target volumes in all but 1 tumor. "Inadequate" coverage in the latter was caused by a new area of atelectasis adjacent to the tumor on the repeat 4DCT. Conclusions: Limited "time trends" were observed in PTVs generated by repeated uncoached 4DCT scans, and the dosimetric consequences proved to be minimal. Treatment based only on the initial PTV would not have resulted in major tumor underdosage, indicating that adaptive treatment planning is of limited value for fractionated stereotactic radiotherapy. (c) 2007 Elsevier Inc.
引用
收藏
页码:1370 / 1374
页数:5
相关论文
共 24 条
[21]   Biologic and physical fractionation effects of random geometric errors [J].
van Herk, M ;
Witte, M ;
van Der Geer, J ;
Schneider, C ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (05) :1460-1471
[22]   Dose-response in stereotactic irradiation of lung tumors [J].
Wulf, J ;
Baier, K ;
Mueller, G ;
Flentje, MP .
RADIOTHERAPY AND ONCOLOGY, 2005, 77 (01) :83-87
[23]   Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver [J].
Wulf, J ;
Hädinger, U ;
Oppitz, U ;
Thiele, W ;
Flentje, M .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) :141-150
[24]   Change in dose distribution of three-dimensional conformal radiotherapy during treatment for lung tumor [J].
Yamada K. ;
Iwai K. ;
Kawamorita R. ;
Okuno Y. ;
Nakajima T. .
Radiation Medicine, 2006, 24 (2) :122-127