The usefulness of simple X-ray powder diffraction analysis for counterfeit control -: The Viagra® example

被引:69
作者
Maurin, Jan K.
Plucinski, Franciszek
Mazurek, Aleksander P.
Fijalek, Zbigniew
机构
[1] Natl Drug Inst, PL-00725 Warsaw, Poland
[2] Inst Atom Energy, PL-05400 Otwock, Poland
[3] Med Univ Warsaw, Fac Pharm, PL-02097 Warsaw, Poland
关键词
X-ray powder diffraction; counterfeit medicines; fast screening; Viagra (R); sildenafil;
D O I
10.1016/j.jpba.2006.10.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Counterfeit and illegally manufactured drugs become a very important problem all over the world, hence, a search for new fast, easy, reliable and not expensive methods of drugs screening is essential. We describe the use of X-ray powder diffraction method for the fast screening of tablets for counterfeit medicines identification. The original Viagra (R) tablets and some counterfeit and/or imitations of Viagra were used as example. We demonstrate the application of diffraction method for discrimination of tablets coatings and for identification of differences in drug composition. The X-ray diffraction method turns out to be very fast and reliable for detecting counterfeits and imitation, and it correctly predicts the presence or absence of active substance and/or particular excipients. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1514 / 1518
页数:5
相关论文
共 11 条
[1]   Chemical characterization of counterfeit captagon tablets seized in Jordan [J].
Alabdalla, MA .
FORENSIC SCIENCE INTERNATIONAL, 2005, 152 (2-3) :185-188
[2]  
[Anonymous], COMBATING COUNTERFEI
[3]  
*COUNC EUR PUBL, 2006, COUNT MED SURV REP
[4]  
FLUECKIGER J, 2005, INFORM EXCHANGE GEN
[5]   Development and validation of a reversed-phase LC method for analysing potentially counterfeit antimalarial medicines [J].
Gaudiano, Maria Cristina ;
Antoniella, Eleonora ;
Bertocchi, Paola ;
Valvo, Luisa .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (01) :132-135
[6]  
*INT CTR DIFFR DAT, PDF 2 PDF 4 POWD DIF
[7]   NIR spectrometry for counterfeit drug detection - A feasibility study [J].
Rodionova, OY ;
Houmoller, LP ;
Pomerantsev, AL ;
Geladi, P ;
Burger, J ;
Dorofeyev, VL ;
Arzamastsev, AP .
ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) :151-158
[8]   Identification of counterfeit drugs using near-infrared spectroscopy [J].
Scafi, SHF ;
Pasquini, C .
ANALYST, 2001, 126 (12) :2218-2224
[9]  
U.S Department of Health and Human Service, 2004, COMB COUNT DRUGS REP
[10]   Screening suspected counterfeit Viagra® and imitations of Viagra® with near-infrared spectroscopy [J].
Vredenbregt, MJ ;
Blok-Tip, L ;
Hoogerbrugge, R ;
Barends, DM ;
de Kaste, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (04) :840-849