PDMS 2D optical lens integrated with microfluidic channels: principle and characterization

被引:175
作者
Camou, S [1 ]
Fujita, H [1 ]
Fujii, T [1 ]
机构
[1] Univ Tokyo, Inst Ind Sci, Meguro Ku, Tokyo 1538505, Japan
来源
LAB ON A CHIP | 2003年 / 3卷 / 01期
关键词
D O I
10.1039/b211280a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, the fabrication and characterization of PDMS 2D-optical lenses are reported. These lenses are designed in order to improve the performance of fluorescent spectroscopy detection performed on a portable chip using optical fibers. The fabrication process of the PDMS layer is first detailed, and the patterns are then checked with a SEM. By comparing various interfacial structures, it is shown that the beam properties of the light coming out from the fiber can be modified depending on the lens curvature radius. As a consequence, for a constant dye concentration, the use of such lenses can increase the intensity of fluorescent response close to the fiber or far from the fiber, compared to the same design with a flat interface. This excitation improvement corresponding to a stronger response from the dye then consequently leads to around three times higher sensitivity of the on-chip detection method for fluorescent spectroscopy.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 28 条
  • [1] CAMOU S, 2001, P IEEE LEOS OPT MEMS, P133
  • [2] CHABINYC ML, 2001, ANAL CHEM
  • [3] Croutxé-Barghorn C, 2000, APPL SURF SCI, V168, P89, DOI 10.1016/S0169-4332(00)00597-3
  • [4] Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system
    Fang, Q
    Wang, FR
    Wang, SL
    Liu, SS
    Xu, SK
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 27 - 37
  • [5] FLETCHER DA, 2001, P IEEE LEOS OPT MEMS, P157
  • [6] Techniques for patterning and guidance of primary culture neurons on micro-electrode arrays
    Griscom, L
    Degenaar, P
    LePioufle, B
    Tamiya, E
    Fujita, H
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3): : 15 - 21
  • [7] MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP
    HARRISON, DJ
    FLURI, K
    SEILER, K
    FAN, ZH
    EFFENHAUSER, CS
    MANZ, A
    [J]. SCIENCE, 1993, 261 (5123) : 895 - 897
  • [8] Hübner J, 2001, REV SCI INSTRUM, V72, P229, DOI 10.1063/1.1326929
  • [9] Fabrication of microlens in photosensitive hybrid sol-gel films using a gray scale mask
    Jiang, HJ
    Yuan, XC
    Yun, ZS
    Chan, YC
    Lam, YL
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2001, 16 (1-2): : 99 - 102
  • [10] Microfabrication of a planar absorbance and fluorescence cell for integrated capillary electrophoresis devices
    Liang, ZH
    Chiem, N
    Ocvirk, G
    Tang, T
    Fluri, K
    Harrison, DJ
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (06) : 1040 - 1046