Efficient measurement and calculation of MR diffusion Anisotropy images using the platonic variance method

被引:26
作者
Akkerman, EM [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
关键词
MRI; diffusion tensor imaging; diffusion anisotropy; fractional anisotropy; Platonic solids;
D O I
10.1002/mrm.10365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Platonic variance method produces MR diffusion anisotropy (DA) images with a minimum amount of computational effort. It can be programmed in a self-contained MR sequence, thus eliminating the need for postprocessing on a separate workstation. The method uses gradient acquisition schemes, based on Platonic solids: the "icosahedric" scheme (N = 6), the "dodecahedric" scheme (N = 10), and combinations thereof. For these schemes the average of the diffusion tensor eigenvalues equals the average of the measured apparent diffusion coefficients (ADCs), and the variance of the eigenvalues equals 5/2 times the variance of the diffusion coefficients. This results in compact expressions for anisotropy measures, directly in terms of the acquired images, i.e., without calculating the eigenvalues or even the tensor elements. The resulting anisotropy images were shown to be identical to the ones traditionally derived. It is expected that this method will considerably promote the routine use of DA imaging. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:599 / 604
页数:6
相关论文
共 19 条
[1]  
Alexander AL, 2000, MAGNET RESON MED, V44, P283, DOI 10.1002/1522-2594(200008)44:2<283::AID-MRM16>3.0.CO
[2]  
2-V
[3]   Invariant and orthonormal scalar measures derived from magnetic resonance diffusion tensor imaging [J].
Bahn, MM .
JOURNAL OF MAGNETIC RESONANCE, 1999, 141 (01) :68-77
[4]  
Bammer R, 2000, MAGNET RESON MED, V44, P583, DOI 10.1002/1522-2594(200010)44:4<583::AID-MRM12>3.0.CO
[5]  
2-O
[6]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[7]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[8]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[9]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[10]   Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results [J].
Conturo, TE ;
McKinstry, RC ;
Akbudak, E ;
Robinson, BH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :399-412