Resonance frequency estimation of a bridged loop-gap resonator used for magnetic resonance measurements

被引:20
作者
Hirata, H
Ono, M
机构
[1] Dept. of Elec. Eng. and Comp. Sci., Yamagata University, Yonezawa, Yamagata, 992
关键词
D O I
10.1063/1.1146554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a method for estimating the resonance frequency of a bridged loop-gap resonator (BLGR). It first describes the structure of the BLGR and its equivalent electrical circuit, and then a procedure for calculating the resonance frequency is revealed. In this procedure, node analysis, which is a circuit theory, is applied to calculate the branch voltages of the equivalent circuit. Finally, this paper reports on the calculations and measurements of the resonance frequency, and the validity of the method for estimating resonance frequency. (C) 1996 American Institute of Physics.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 18 条
[1]   ELECTRON-PARAMAGNETIC RESONANCE SPECTROMETER FOR 3-DIMENSIONAL INVIVO IMAGING AT VERY LOW-FREQUENCY [J].
ALECCI, M ;
DELLAPENNA, S ;
SOTGUI, A ;
TESTA, L ;
VANNUCCI, I .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4263-4270
[2]  
COLLIN RE, 1966, F MICROWAVE ENG, pCH3
[3]  
DESOER CA, 1969, BASIC CIRCUIT THEORY, pCH10
[4]   THE LOOP-GAP RESONATOR - A NEW MICROWAVE LUMPED CIRCUIT ELECTRON-SPIN-RESONANCE SAMPLE STRUCTURE [J].
FRONCISZ, W ;
HYDE, JS .
JOURNAL OF MAGNETIC RESONANCE, 1982, 47 (03) :515-521
[5]   MULTIGAP PARALLEL-PLATE BRACELET RESONATOR FREQUENCY DETERMINATION AND APPLICATIONS [J].
GONORD, P ;
KAN, S ;
LEROYWILLIG, A ;
WARY, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (11) :3363-3366
[6]   SPLIT-RING RESONATOR FOR USE IN MAGNETIC-RESONANCE FROM 200-2000 MHZ [J].
HARDY, WN ;
WHITEHEAD, LA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (02) :213-216
[7]   DISPERSION ELECTRON-SPIN RESONANCE WITH THE LOOP-GAP RESONATOR [J].
HYDE, JS ;
FRONCISZ, W ;
KUSUMI, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (12) :1934-1937
[8]   AN ESR-CT IMAGING OF THE HEAD OF A LIVING RAT RECEIVING AN ADMINISTRATION OF A NITROXIDE RADICAL [J].
ISHIDA, S ;
MATSUMOTO, S ;
YOKOYAMA, H ;
MORI, N ;
KUMASHIRO, H ;
TSUCHIHASHI, N ;
OGATA, T ;
YAMADA, M ;
ONO, M ;
KITAJIMA, T ;
KAMADA, H ;
YOSHIDA, E .
MAGNETIC RESONANCE IMAGING, 1992, 10 (01) :109-114
[9]   AN ANALYSIS OF THE EFFECTS OF EDDY CURRENTS ON L-BAND EPR-SPECTRA [J].
JIANG, JJ ;
LIU, KJ ;
WALCZAK, T ;
SWARTZ, HM .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 106 (03) :220-226
[10]  
KEIJZERS CP, 1989, PULSED EPR NEW FIELD, pCH3