Depth profile of diffuse reflectance near-infrared spectroscopy for measurement of water content in skin

被引:79
作者
Arimoto, H
Egawa, M
Yamada, Y
机构
[1] Natl Inst Adv Ind Sci & Technol, Human Biomed Inst, Tsukuba, Ibaraki 3058564, Japan
[2] SHISEIDO, Life Sci Res Ctr, Yokohama, Kanagawa, Japan
[3] Univ Electrocommun, Tokyo, Japan
关键词
measurement depth; near-infrared spectroscopy; stratum corneum; water content;
D O I
10.1111/j.1600-0846.2005.00093.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background/purpose: The penetration depth of light in diffuse reflectance near-infrared spectroscopy for measuring water content in skin is assessed both from theoretical and experimental points of view. Methods: The Monte Carlo simulation was implemented to investigate the dependencies of the light penetration depth on a source-detector distance. To compare with the simulation results, an in vivo experiment for water contents of skin was performed introducing two different optical fiber probes. Results: It is found that the minimum separation between a source and detector fibers influences largely the measurement depth. The larger separation leads to a deeper measurement depth at a particular wavelength. The measurement depth is also influenced fairly by the absorption coefficient of the tissue. The larger absorption coefficient results in a shallower measurement depth. Conclusion: The correlations between the water contents measured by the optical and capacitance techniques were discussed. The dependencies of the light penetration depth on the source-detector geometry and wavelength are presented.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 20 条
[11]  
MARTIN K, 1995, NEAR INFRARED SPECTR, P328
[12]  
MARTIN KA, 1993, J SOC COSMET CHEM, V44, P249
[13]   Optical glucose sensing in biological fluids:: an overview [J].
McNichols, RJ ;
Coté, GL .
JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (01) :5-16
[14]  
RIGAL J, 1993, J SOC COSMET CHEM, V44, P197
[15]   LIGHT-SCATTERING IN INTRALIPID-10-PERCENT IN THE WAVELENGTH RANGE OF 400-1100 NM [J].
VANSTAVEREN, HJ ;
MOES, CJM ;
VANMARLE, J ;
PRAHL, SA ;
VANGEMERT, MJC .
APPLIED OPTICS, 1991, 30 (31) :4507-4514
[16]  
WALLING PL, 1989, J SOC COSMET CHEM, V40, P151
[17]  
Williams P., 2001, NEAR INFRARED TECHNO
[18]   Development of a method for the determination of human skin moisture using a portable near-infrared system [J].
Woo, YA ;
Ahn, JW ;
Chun, IK ;
Kim, HJ .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4964-4971
[19]   Integrated endoscopy system for simultaneous imaging and spectroscopy for early lung cancer detection [J].
Zeng, HS ;
Petek, M ;
Zorman, MT ;
McWilliams, A ;
Palcic, B ;
Lam, S .
OPTICS LETTERS, 2004, 29 (06) :587-589
[20]   Number of cell layers of the stratum corneum in normal skin - relationship to the anatomical location on the body, age, sex and physical parameters [J].
Zhen, YX ;
Suetake, T ;
Tagami, H .
ARCHIVES OF DERMATOLOGICAL RESEARCH, 1999, 291 (10) :555-559