Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

被引:39
作者
Doo, Kyung Won [1 ]
Kang, Eun-Young [1 ]
Yong, Hwan Seok [1 ]
Ham, Soo-Youn [2 ]
Lee, Ki Yeol [3 ]
Choo, Ji Yung [3 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Radiol, Seoul 152703, South Korea
[2] Korea Univ, Coll Med, Anam Hosp, Dept Radiol, Seoul 152703, South Korea
[3] Korea Univ, Coll Med, Ansan Hosp, Dept Radiol, Ansan, South Korea
关键词
Pulmonary nodule; Digital tomosynthesis; Computed tomography; Thoracic imaging; Radiography; PULMONARY NODULES; DIAGNOSTIC-PERFORMANCE; COMPUTED-TOMOGRAPHY; BRONCHIOLOALVEOLAR CARCINOMA; CT; LUNG; MANAGEMENT; RECONSTRUCTION; DISEASE; SYSTEM;
D O I
10.1007/s00330-014-3376-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
The purpose of this study was to evaluate the diagnostic performance of chest radiography (CXR), chest digital tomosynthesis (DT) and low dose multidetector computed tomography (LDCT) for the detection of small pulmonary ground-glass opacity (GGO) nodules, using an anthropomorphic chest phantom. Artificial pulmonary nodules were placed in a phantom and a total of 40 samples of different nodule settings underwent CXR, DT and LDCT. The images were randomly read by three experienced chest radiologists. Free-response receiver-operating characteristics (FROC) were used. The figures of merit for the FROC curves averaged for the three observers were 0.41, 0.37 and 0.76 for CXR, DT and LDCT, respectively. FROC analyses revealed significantly better performance of LDCT over CXR or DT for the detection of GGO nodules (P < 0.05). The difference in detectability between CXR and DT was not statistically significant (P = 0.73). The diagnostic performance of DT for the detection of pulmonary small GGO nodules was not significantly different from that of CXR, but LDCT performed significantly better than both CXR and DT. DT is not a suitable alternative to CT for small GGO nodule detection, and LDCT remains the method of choice for this purpose. aEuro cent For GGO nodule detection, DT was not significantly different from CXR. aEuro cent DT is not a suitable alternative to CT for GGO nodule detection. aEuro cent LDCT is the method of choice for GGO nodule detection.
引用
收藏
页码:3269 / 3276
页数:8
相关论文
共 26 条
[1]
Digital tomosynthesis of the chest for lung nodule detection: Interim sensitivity results from an ongoing NIH-sponsored trial [J].
Dobbins, James T. ;
McAdams, H. Page ;
Song, Jae-Woo ;
Li, Christina M. ;
Godfrey, Devon J. ;
DeLong, David M. ;
Paik, Sang-Hyun ;
Martinez-Jimenez, Santiago .
MEDICAL PHYSICS, 2008, 35 (06) :2554-2557
[2]
Clinical utility of chest roentgenograms [J].
Geitung, JT ;
Skjærstad, LM ;
Göthlin, JH .
EUROPEAN RADIOLOGY, 1999, 9 (04) :721-723
[3]
Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study [J].
Gomi, T. ;
Nakajima, M. ;
Fujiwara, H. ;
Takeda, T. ;
Saito, K. ;
Umeda, T. ;
Sakaguchi, K. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1017) :E622-E629
[4]
Nodule detection in digital chest radiography:: Effect of system noise [J].
Håkansson, M ;
Båth, M ;
Börjesson, S ;
Kheddache, S ;
Johnsson, ÅA ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :97-101
[5]
Optimal image reconstruction for detection and characterization of small pulmonary nodules during low-dose CT [J].
Hashemi, SayedMasoud ;
Mehrez, Hatem ;
Cobbold, Richard S. C. ;
Paul, Narinder S. .
EUROPEAN RADIOLOGY, 2014, 24 (06) :1239-1250
[6]
Detectability of peripheral lung cancer on chest radiographs: effect of the size, location and extent of ground-glass opacity [J].
Hayashi, H. ;
Ashizawa, K. ;
Uetani, M. ;
Futagawa, S. ;
Fukushima, A. ;
Minami, K. ;
Honda, S. ;
Hayashi, K. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (976) :272-278
[7]
Differential diagnosis of ground-glass opacity nodules - CT number analysis by three-dimensional computerized quantification [J].
Ikeda, Koei ;
Awai, Kazuo ;
Mori, Takeshi ;
Kawanaka, Koichi ;
Yamashita, Yasuyuki ;
Nomori, Hiroaki .
CHEST, 2007, 132 (03) :984-990
[8]
Chest Tomosynthesis: Technical and Clinical Perspectives [J].
Johnsson, Ase Allansdotter ;
Vikgren, Jenny ;
Bath, Magnus .
SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 35 (01) :17-26
[9]
Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Yasaka, Koichiro ;
Hanaoka, Shohei ;
Akai, Hiroyuki ;
Sato, Jiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
INVESTIGATIVE RADIOLOGY, 2013, 48 (04) :206-212
[10]
Pulmonary Mycobacterial Disease: Diagnostic Performance of Low-Dose Digital Tomosynthesis as Compared with Chest Radiography [J].
Kim, Eun Young ;
Chung, Myung Jin ;
Lee, Ho Yun ;
Koh, Won-Jung ;
Jung, Hye Na ;
Lee, Kyung Soo .
RADIOLOGY, 2010, 257 (01) :269-277