Imaging and velocimetry of the human retinal circulation with color Doppler optical coherence tomography

被引:140
作者
Yazdanfar, S [1 ]
Rollins, AM
Izatt, JA
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Med, Cleveland, OH 44106 USA
关键词
D O I
10.1364/OL.25.001448
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Noninvasive monitoring of blood flow in retinal microcirculation may elucidate the progression and treatment of ocular disorders, including diabetic retinopathy, age-related macular degeneration, and glaucoma. Color Doppler optical coherence tomography (CDOCT) is a technique that allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue microstructure and blood flow in living tissues. CDOCT is demonstrated for the first time in living human subjects for bidirectional blood-flow mapping of retinal vasculature. (C) 2000 Optical Society of America.
引用
收藏
页码:1448 / 1450
页数:3
相关论文
共 14 条
[1]  
Alm A., 1992, Adler's physiology of the eye, P198
[2]  
*AM NAT STAND I, 1993, Z1361 ANSI LAS I AM
[3]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[4]   Regulation of retinal and optic nerve blood flow [J].
Harris, A ;
Ciulla, TA ;
Chung, HS ;
Martin, B .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (11) :1491-1495
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy [J].
Izatt, JA ;
Kulkami, MD ;
Yazdanfar, S ;
Barton, JK ;
Welch, AJ .
OPTICS LETTERS, 1997, 22 (18) :1439-1441
[7]   Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography [J].
Kulkarni, MD ;
van Leeuwen, TG ;
Yazdanfar, S ;
Izatt, JA .
OPTICS LETTERS, 1998, 23 (13) :1057-1059
[8]   Accuracy and noise in optical Doppler tomography studied by Monte Carlo simulation [J].
Lindmo, T ;
Smithies, DJ ;
Chen, ZP ;
Nelson, JS ;
Milner, TE .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :3045-3064
[9]  
RIVA CE, 1990, LASER DOPPLER BLOOD, P349
[10]   Optical properties of circulating human blood in the wavelength range 400-2500 NM [J].
Roggan, A ;
Friebel, M ;
Dörschel, K ;
Hahn, A ;
Müller, G .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :36-46