Ratio measurements in oxygen determinations: wavelength ratiometry, lifetime discrimination, and polarization detection

被引:21
作者
Kostov, Y [1 ]
Rao, G [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Baltimore, MD 21250 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2003年 / 90卷 / 1-3期
关键词
optical oxygen sensors; radiometric sensor; polarization sensor;
D O I
10.1016/S0925-4005(03)00040-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work we present ratiometric measurements of oxygen concentrations using a dual-emitting dye. Three different methods for ratio measurements in oxygen sensing are employed. The standard wavelength-ratiometric approach is simple to implement, but the sensor response has significant non-linearity. The frequency discrimination of the lifetimes allows for measurements of dual-emission ratio through a single emission filter. In this case the Stern-Volmer plots are linear. Another option is to use emission polarization. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 142
页数:4
相关论文
共 10 条
[1]  
[Anonymous], 1994, TOPICS FLUORESCENCE
[2]   Ratiometric and fluorescence lifetime-based biosensors incorporating cytochrome c′ and the detection of extra- and intracellular macrophage nitric oxide [J].
Barker, SLR ;
Clark, HA ;
Swallen, SF ;
Kopelman, R ;
Tsang, AW ;
Swanson, JA .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1767-1772
[3]   Synthesis and characterization of dual-wavelength Cl--sensitive fluorescent indicators for ratio imaging [J].
Jayaraman, S ;
Biwersi, J ;
Verkman, AS .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1999, 276 (03) :C747-C757
[4]   Ratiometric oxygen sensing: detection of dual-emission ratio through a single emission filter [J].
Kostov, Y ;
Harms, P ;
Pilato, RS ;
Rao, G .
ANALYST, 2000, 125 (06) :1175-1178
[5]   Polarization oxygen sensor: a template for a class of fluorescence based sensors [J].
Kostov, Y ;
Gryczynski, Z ;
Rao, G .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2167-2171
[6]   Unique oxygen analyzer combining a dual emission probe and a low-cost solid-state ratiometric fluorometer [J].
Kostov, Y ;
Van Houten, KA ;
Harms, P ;
Pilato, RS ;
Rao, G .
APPLIED SPECTROSCOPY, 2000, 54 (06) :864-868
[7]   FIBER OPTIC SENSOR BASED ON FLUORESCENCE QUENCHING OF EVANESCENT-WAVE EXCITED RUTHENIUM COMPLEXES IN SOL-GEL DERIVED POROUS COATINGS [J].
MACCRAITH, BD ;
MCDONAGH, CM ;
OKEEFE, G ;
KEYES, TE ;
VOS, JG ;
OKELLY, B ;
MCGILP, JF .
ANALYST, 1993, 118 (04) :385-388
[8]   Approximation of calibration of phase-fluorimetric oxygen sensors on the basis of physical models [J].
Ogurtsov, VI ;
Papkovsky, DB ;
Papkovskaia, NY .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 81 (01) :17-24
[9]  
Spichiger-Keller U. E., 1998, CHEM SENSORS BIOSENS
[10]   Functionalized 2-pyridyl-substituted metallo-1,2-enedithiolates.: Synthesis, characterization, and photophysical properties of (dppe)M{S2C2(2-pyridine(ium))(CH2CH2OR")} and (dppe)M[{S2C2(CH2CH2-N-2-pyridinium}]+ (R" = H, acetyl, lauroyl; M = Pd, Pt; dppe = 1,2-bis(diphenylphosphino)ethane) [J].
Van Houten, KA ;
Heath, DC ;
Barringer, CA ;
Rheingold, AL ;
Pilato, RS .
INORGANIC CHEMISTRY, 1998, 37 (18) :4647-4653