RP-LC x RP-LC analysis of a tryptic digest using a combination of totally porous and partially porous stationary phases

被引:32
作者
Mondello, Luigi [1 ,2 ]
Donato, Paola [1 ,2 ]
Cacciola, Francesco [1 ]
Fanali, Chiara [2 ,3 ]
Dugo, Paola [1 ,2 ]
机构
[1] Univ Messina, Fac Farm, Dipartimento Farmacochim, I-98168 Messina, Italy
[2] Campus Biomed, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Biochim & Biochim Clin, Rome, Italy
关键词
Comprehensive RP-LC x RP-LC; Partially porous particles; Peptides; Proteome analysis; Tryptic digest; 2-DIMENSIONAL LIQUID-CHROMATOGRAPHY; PEPTIDE RETENTION PREDICTION; REVERSED-PHASE; MASS-SPECTROMETRY; PEAK-CAPACITY; PROTEIN IDENTIFICATION; OFF-LINE; GEL-ELECTROPHORESIS; PROTEOMIC ANALYSIS; SEPARATION;
D O I
10.1002/jssc.200900816
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different chromatographic separation modes have been combined, in off-line and on-line approaches, attempting to achieve enhanced separation power for the analysis of complex proteome samples. Among these, the use of RP-LC x RP-LC brings in the added advantages of high peak capacity in both dimensions, capability of full automation, and the likelihood of direct hyphenation to MS. In this contribution, we achieved enhanced resolution in the first dimension, by serially coupling Bio wide pore C18 columns at basic pH, at moderate pressure. Selectivity was tuned using one short (3 cm) C18 column packed with partially porous particles for fast second-dimension analysis, operated at acidic pH. The comprehensive system was configured around electronically activated two-position, ten-port valve for within-loop automated fraction collection/re-injection. A theoretical peak capacity of 3796 was calculated for the set-up employing one basic column in the first dimension, while a peak capacity of 10 686 was attained with four times the length of stationary phase, even at the expense of longer analysis time. The system showed very good reproducibility of retention times and chromatographic peak areas (RSD less than 1.2 and 4%, respectively).
引用
收藏
页码:1454 / 1461
页数:8
相关论文
共 81 条
[61]  
2-2
[62]  
PREMSTALLER A, 2005, ANAL CHEM, V77, P6426
[63]  
Rabilloud T, 2002, PROTEOMICS, V2, P3, DOI 10.1002/1615-9861(200201)2:1<3::AID-PROT3>3.0.CO
[64]  
2-R
[65]   The complete yeast mitochondrial proteome: Multidimensional separation techniques for mitochondrial proteomics [J].
Reinders, Joerg ;
Zahedi, Rene P. ;
Pfanner, Nikolaus ;
Meisinger, Chris ;
Sickmann, Albert .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (07) :1543-1554
[66]   Highly efficient peptide separations in proteomics Part 2: Bi- and multidimensional liquid-based separation techniques [J].
Sandra, Koen ;
Moshir, Mahan ;
D'hondt, Filip ;
Tuytten, Robin ;
Verleysen, Katleen ;
Kas, Koen ;
Francois, Isabelle ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (11-12) :1019-1039
[67]   Proteome analysis of Myxococcus xanthus by off-line two-dimensional chromatographic separation using monolithic poly-(styrene-divinylbenzene) columns combined with ion-trap tandem mass spectrometry [J].
Schley, Christian ;
Altmeyer, Matthias O. ;
Swart, Remco ;
Mueller, Rolf ;
Huber, Christian G. .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (10) :2760-2768
[68]   High-efficiency capillary isoelectric focusing of peptides [J].
Shen, YF ;
Berger, SJ ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2154-2159
[69]   Ultra-high-efficiency strong cation exchange LC/RPLC/MS/MS for high dynamic range characterization of the human plasma proteome [J].
Shen, YF ;
Jacobs, JM ;
Camp, DG ;
Fang, RH ;
Moore, RJ ;
Smith, RD ;
Xiao, WZ ;
Davis, RW ;
Tompkins, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1134-1144
[70]  
Simpson R.J., 2003, PROTEINS PROTEOMICS