Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation

被引:43
作者
Heist, E. Kevin
Chevalier, Jianping
Holmvang, Godtfred
Singh, Jagmeet P.
Ellinor, Patrick T.
Milan, David J.
D'Avila, Andre
Mela, Theofanie
Ruskin, Jeremy N.
Mansour, Moussa
机构
[1] Massachusetts Gen Hosp, Cardiac Arrhythmia Serv, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Cardiac Unit, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02115 USA
关键词
atrial fibrillation; catheter ablation; image integration; electroanatomic mapping;
D O I
10.1007/s10840-006-9060-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Integration of 3-D electroanatomic mapping with Computed Tomographic (CT) and Magnetic Resonance (MR) imaging is gaining acceptance to facilitate catheter ablation of atrial fibrillation. This is critically dependent on accurate integration of electroanatomic maps with CT or MR images. We sought to examine the effect of patient- and technique-related factors on integration accuracy of electroanatomic mapping with CT and MR imaging of the left atrium. Materials and methods Sixty-one patients undergoing catheter-based atrial fibrillation (AF) ablation procedures were included. All patients underwent cardiac CT (n = 11) or MR (n = 50) imaging, and image integration with real-time electroanatomic mapping of the aorta and left atrium (LA). CARTO-Merge software (Biosense-Webster) was used to calculate the overall average accuracy of integration of electroanatomic points with the CT and MR-derived reconstructions of the LA and aorta. Results There was a significant correlation between LA size assessed by electroanatomic mapping (112 +/- 31 ml) and average integration error (1.9 +/- 0.6 mm) (r = 0.46, p = 0.0003). There was also greater integration error for patients with LA volume >= 110 ml (n = 31) < 10 ml (n = 31) (p = 0.004). In contrast, there was no significant association between average integration error and paroxysmal versus persistent AF, left ventricular ejection fraction, days from imaging to electroanatomic mapping, or images derived from CT versus MR. Conclusions Patients with larger LA volume may be prone to greater error during integration of electroanatomic mapping with CT and MR imaging. Strategies to reduce integration error may therefore be especially useful in patients with large LA volume.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 17 条
  • [1] Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
    Dong, J
    Calkins, H
    Solomon, SB
    Lai, SH
    Dalal, D
    Lardo, A
    Brem, E
    Preiss, A
    Berger, RD
    Halperin, H
    Dickfeld, T
    [J]. CIRCULATION, 2006, 113 (02) : 186 - 194
  • [2] Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation
    Ernst, S
    Ouyang, FF
    Linder, C
    Hertting, K
    Stahl, F
    Chun, J
    Hachiya, H
    Bänsch, D
    Antz, M
    Kuck, KH
    [J]. CIRCULATION, 2004, 109 (12) : 1472 - 1475
  • [3] Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Takahashi, A
    Hocini, M
    Quiniou, G
    Garrigue, S
    Le Mouroux, A
    Le Métayer, P
    Clémenty, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) : 659 - 666
  • [4] Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation
    Kistler, PM
    Earley, MJ
    Harris, S
    Abrams, D
    Ellis, S
    Sporton, SC
    Schilling, RJ
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (04) : 341 - 348
  • [5] Three-dimensional anatomy of the left atrium by magnetic resonance angiography: Implications for catheter ablation for atrial fibrillation
    Mansour, M
    Refaat, M
    Heist, EK
    Mela, T
    Cury, R
    Holmvang, G
    Ruskin, JN
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (07) : 719 - 723
  • [6] Efficacy and safety of segmental ostial versus circumferential extra-ostial pulmonary vein isolation for atrial fibrillation
    Mansour, M
    Ruskin, J
    Keane, D
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (05) : 532 - 537
  • [7] Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: Implications for catheter ablation techniques for atrial fibrillation
    Mansour, M
    Holmvang, G
    Sosnovik, D
    Migrino, R
    Abbara, S
    Ruskin, J
    Keane, D
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (04) : 387 - 393
  • [8] Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation
    Mikaelian, BJ
    Malchano, ZJ
    Neuzil, P
    Weichet, J
    Doshi, SK
    Ruskin, JN
    Reddy, VY
    [J]. CIRCULATION, 2005, 112 (02) : E35 - E36
  • [9] The impact of respiration on left atrial and pulmonary venous anatomy: Implications for image-guided intervention
    Noseworthy, PA
    Malchano, ZJ
    Ahmed, J
    Holmvang, G
    Ruskin, JN
    Reddy, VY
    [J]. HEART RHYTHM, 2005, 2 (11) : 1173 - 1178
  • [10] Catheter ablation for paroxysmal atrial fibrillation - Segmental pulmonary vein ostial ablation versus left atrial ablation
    Oral, H
    Scharf, C
    Chugh, A
    Hall, B
    Cheung, P
    Good, E
    Veerareddy, S
    Pelosi, F
    Morady, F
    [J]. CIRCULATION, 2003, 108 (19) : 2355 - 2360