Flow injection analysis of water vapour based on a fluorosensor

被引:2
作者
Choi, MMF [1 ]
Tse, OL [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon Tong, Hong Kong, Peoples R China
关键词
fluorescence; organogel; water vapour; flow injection;
D O I
10.1016/S0003-2670(00)01136-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new fluorimetric sensor incorporated with flow injection (FI) technique has been developed for water vapour quantification. The sensor was fabricated by immobilising rhodamine 6G in an organogel deposited on an overhead transparency film. The organogel was prepared from a solution of gelatine, rhodamine 6G and sodium bis(2-ethylhexyl)sulphosuccinate (AOT) in water-isooctane. Isooctane was employed as the organic solvent and AOT as the surfactant, thus forming water-in-oil microemulsions with a high capacity for water solubilisation. The organogel-based optode membrane showed a strong fluorescence at 564 nm when it was excited at 540 nm. The fluorescence intensity of the optode membrane at 564 nm decreased upon exposure to water vapour. The sensing system exhibited a relatively wide linear dynamic range from 0.252 to 2.52 kPa water vapour pressure and also demonstrated a good linearity (correlation coefficient was 0.9912) at 20.0 degreesC and 1 atm pressure. The sensor had good repeatability, photostability and long-term stability. Oxygen, carbon dioxide gases, acetone, toluene, ethanol, chloroform, acetic acid vapours and NO, did not cause any interference. The addition of AOT to the organogel was shown to enhance the sensitivity for the detection of water vapour and also shortened the exposure and recovery times in which 1 cycle of Fl was completed within 1 min. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 44 条
[11]  
Drain D. C., 1997, HDB EXPT METHODS PRO
[12]  
FENDLER JH, 1994, MEMBRANE MIMETIC APP, P49
[13]   NEAR-INFRARED MEASUREMENT OF RELATIVE AND ABSOLUTE-HUMIDITY THROUGH DETECTION OF WATER ADSORBED ON A SILICA-GEL LAYER [J].
FONG, A ;
HIEFTJE, GM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1139-1146
[14]   HYDROCARBON GELS FROM WATER-IN-OIL MICROEMULSIONS [J].
HAERING, G ;
LUISI, PL .
JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (22) :5892-5895
[15]   SAW sensors for the room-temperature measurement of CO2 and relative humidity [J].
Hoyt, AE ;
Ricco, AJ ;
Bartholomew, JW ;
Osbourn, GC .
ANALYTICAL CHEMISTRY, 1998, 70 (10) :2137-2145
[16]   AMPEROMETRIC MICROSENSOR FOR WATER [J].
HUANG, HL ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1935-1942
[17]  
Jenta TRJ, 1997, BIOTECHNOL BIOENG, V53, P121, DOI 10.1002/(SICI)1097-0290(19970120)53:2<121::AID-BIT1>3.0.CO
[18]  
2-Q
[19]  
KIJIMA T, 1996, SENSOR ACTUAT B-CHEM, V35, P388
[20]   Harmonic frequency analysis of SAW resonator chemical sensors: application to the detection of carbon dioxide and humidity [J].
Korsah, K ;
Ma, CL ;
Dress, B .