The European Photon Imaging Camera on XMM-Newton:: The MOS cameras

被引:1961
作者
Turner, MJL [1 ]
Abbey, A
Arnaud, M
Balasini, M
Barbera, M
Belsole, E
Bennie, PJ
Bernard, JP
Bignami, GF
Boer, M
Briel, U
Butler, I
Cara, C
Chabaud, C
Cole, R
Collura, A
Conte, M
Cros, A
Denby, M
Dhez, P
Di Coco, G
Dowson, J
Ferrando, P
Ghizzardi, S
Gianotti, F
Goodall, CV
Gretton, L
Griffiths, RG
Hainaut, O
Hochedez, JF
Holland, AD
Jourdain, E
Kendziorra, E
Lagostina, A
Laine, R
La Palombara, N
Lortlolary, M
Lumb, D
Marty, P
Molendi, S
Pigot, C
Poindron, E
Pounds, KA
Reeves, JN
Reppin, C
Rothenflug, R
Salvetat, P
Sauvageot, JL
Schmitt, D
Sembay, S
机构
[1] Univ Leicester, Dept Phys & Astron, Leicester LE1 7RH, Leics, England
[2] CEA Saclay, DAPNIA Serv Astrophys, DSM, CEA, F-91191 Gif Sur Yvette, France
[3] Ctr Etud Spatiale Rayonnements, F-31028 Toulouse 4, France
[4] MPE, D-85740 Garching, Germany
[5] Univ Birmingham, Sch Phys & Astron, Birmingham B15 2TT, W Midlands, England
[6] Univ Paris 11, Lab Utilisat Rayonnement Electromagnet, F-91405 Orsay, France
[7] IFC Milan, I-20133 Milan, Italy
[8] IAAP Tuebingen, D-72076 Tubingen, Germany
[9] European Space Agcy, ESTEC, PX, NL-2200 AG Noordwijk, Netherlands
[10] Osserv Astron Palermo, I-90134 Palermo, Italy
[11] ITESRE, I-41010 Bologna, Italy
[12] Univ Paris 11, Inst Astrophys Spatiale, F-91405 Orsay, France
[13] Laben SpA, SS Padana Super, I-20090 Milan, Italy
[14] European Space Agcy, Estec, Dept Space Sci, NL-2200 AG Noordwijk, Netherlands
来源
ASTRONOMY & ASTROPHYSICS | 2001年 / 365卷 / 01期
关键词
instrumentation : detectors; X-rays : general;
D O I
10.1051/0004-6361:20000087
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record the images and spectra of celestial X-ray sources focused by the three X-ray mirrors. There is one camera at the focus of each mirror; two of the cameras contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a circular field of view of 30' diameter in each case. The CCDs were specially developed for EPIC, and combine high quality; imaging with spectral resolution close to the Fano limit. A filter wheel carrying three kinds of X-ray transparent light blocking filter, a fully closed, and a fully open position, is fitted to each EPIC instrument. The CCDs are cooled passively and are under full closed loop thermal control. A radio-active source is fitted for internal calibration. Data are processed on-board to sate telemetry by removing cosmic ray tracks, and generating X-ray event files; a variety of different instrument modes are available to increase the dynamic range of the instrument and to enable fast timing. The instruments were calibrated using laboratory X-ra;rr beams, and synchrotron generated monochromatic X-ray beams before launch; in-orbit calibration makes use of a variety of celestial X-ray; targets. The current calibration is better than 10% over the entire energy range of 0.2 to 10 keV. All three instruments survived launch and are performing nominally in orbit. In particular full field-of-view coverage is available, all electronic modes work, and the energy resolution is close to pre-launch values. Radiation damage is well within pre-launch predictions and does not yet impact on the energy resolution. The scientific results from EPIC amply fulfil pre-launch expectations.
引用
收藏
页码:L27 / L35
页数:9
相关论文
共 21 条
[1]   Imaging performance of the XMM-Newton X-ray telecopes [J].
Aschenbach, B ;
Briel, U ;
Haberl, F ;
Bräuninger, H ;
Burkert, W ;
Oppitz, A ;
Gondoin, P ;
Lumb, D .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 :731-739
[2]   Pile-up on X-ray CCD instruments [J].
Ballet, J .
ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1999, 135 (02) :371-381
[3]   The CESR multi-mission radiation monitor [J].
Boer, M ;
Naya, J ;
Chabaud, JP ;
Ehanno, M ;
Rouaix, G ;
Baiget, A ;
Ecoffet, R ;
Labrunee, M ;
Calvel, P ;
Reveret, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) :2010-2016
[4]  
BUTLER IG, 2000, UNPUB J AERO ENG
[5]   The reflection grating spectrometer on board XMM-Newton [J].
den Herder, JW ;
Brinkman, AC ;
Kahn, SM ;
Branduardi-Raymont, G ;
Thomsen, K ;
Aarts, H ;
Audard, M ;
Bixler, JV ;
den Boggende, AJ ;
Cottam, J ;
Decker, T ;
Dubbeldam, L ;
Erd, C ;
Goulooze, H ;
Güdel, M ;
Guttridge, P ;
Hailey, CJ ;
Al Janabi, K ;
Kaastra, JS ;
de Korte, PAJ ;
van Leeuwen, BJ ;
Mauche, C ;
McCalden, AJ ;
Mewe, R ;
Naber, A ;
Paerels, FB ;
Peterson, JR ;
Rasmussen, AP ;
Rees, K ;
Sakelliou, I ;
Sako, M ;
Spodek, J ;
Stern, M ;
Tamura, T ;
Tandy, J ;
de Vries, CP ;
Welch, S ;
Zehnder, A .
ASTRONOMY & ASTROPHYSICS, 2001, 365 (01) :L7-L17
[6]   Institut d'Astrophysique Spatiale (IAS) 0.1-15KeV synchrotron radiation facility beam lines. [J].
Dhez, P ;
Jourdain, E ;
Hainaut, O ;
Hochedez, JF ;
Labeque, A ;
Salvetat, P ;
Song, XY .
EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 :134-142
[7]  
Ferrando P, 1999, ASTRON NACHR, V320, P379, DOI 10.1002/1521-3994(199908)320:4/5<379::AID-ASNA379>3.0.CO
[8]  
2-0
[9]  
HOLLAND A, 1990, P SOC PHOTO-OPT INS, V1344, P378, DOI 10.1117/12.23266
[10]   THE EFFECT OF BULK TRAPS IN PROTON IRRADIATED EEV CCDS [J].
HOLLAND, AD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :335-343