PMMA particles and pressure - a study of the osteolytic properties of two agents proposed to cause prosthetic loosening

被引:40
作者
Skoglund, B [1 ]
Aspenberg, P [1 ]
机构
[1] Linkoping Univ, Fac Hlth Sci, INR, Div Orthopaed & Sports Med,Dept Neurosci & Locomo, SE-58185 Linkoping, Sweden
关键词
D O I
10.1016/S0736-0266(02)00150-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Amongst the wear debris particles implicated in the particle hypothesis for prosthetic loosening are polymethylmethacrylate (PMMA), and particularly PMMA with barium sulphate contrast agent. Another suggested cause for loosening is hydrostatic pressure. PMMA particles were combined with hydrostatic pressure in a study to investigate whether there could be a synergistic or additive effect between these two factors. Titanium plates were fastened onto tibiae of 59 rats. After osseointegration, PMMA particles with barium sulphate were administered to the bone-implant interface. Further, PMMA particles were introduced into a previously published model for hydrostatic pressure induced osteolysis. There was measurable resorption in response to the PMMA particles but no additive or synergistic effect from introducing particles to the pressure model, and the effect of pressure was far greater than that of particles. These results suggest that, whereas particles can be shown to elicit an osteolytic response, the much less studied osteolytic effects of pressure could be far more important. (C) 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 31 条
[1]
The effects of particulate polyethylene at a weight-bearing bone-implant interface - A study in rats [J].
Allen, M ;
Brett, F ;
Millett, P ;
Rushton, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :32-37
[2]
ALLEN MJ, 1997, J BONE JOINT SURG BR, V79, P457
[3]
Periprosthetic bone resorption - Particles versus movement [J].
Aspenberg, P ;
Herbertsson, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :641-646
[4]
BI Y, 1999, ADH END EX ORTH IMPL
[5]
The effect of cyclic pressure on human monocyte-derived macrophages in vitro [J].
Ferrier, GM ;
McEvoy, A ;
Evans, CE ;
Andrew, JG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (05) :755-759
[6]
MECHANICAL INFLUENCES ON TISSUE DIFFERENTIATION AT BONE-CEMENT INTERFACES [J].
GIORI, NJ ;
RYD, L ;
CARTER, DR .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :514-522
[7]
Goodman SB, 1998, CLIN ORTHOP RELAT R, P25
[8]
OSTEOLYSIS AND PARTICLE DISEASE IN HIP-REPLACEMENT - A REVIEW [J].
HARRIS, WH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (01) :113-123
[9]
ARTHROGRAPHY AFTER TOTAL HIP-ARTHROPLASTY - A MODIFIED TECHNIQUE USED IN THE DIAGNOSIS OF PAIN [J].
HENDRIX, RW ;
WIXSON, RL ;
RANA, NA ;
ROGERS, LF .
RADIOLOGY, 1983, 148 (03) :647-652
[10]
Production of TNF-α and bone resorbing activity by macrophages in response to different types of bone cement particles [J].
Ingham, E ;
Green, TR ;
Stone, MH ;
Kowalski, R ;
Watkins, N ;
Fisher, J .
BIOMATERIALS, 2000, 21 (10) :1005-1013