Application of finite difference time domain method for the design of birdcage RF head coils using multi-port excitations

被引:90
作者
Ibrahim, TS
Lee, R
Baertlein, BA
Kangarlu, A
Robitaille, PML [1 ]
机构
[1] Ohio State Univ, Dept Elect Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
RF coil modeling; SAR; B-1; field; multi-port excitation;
D O I
10.1016/S0730-725X(00)00143-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A three-dimensional finite difference time domain model was developed where the high pass birdcage coil and the imaged object are analysed as a single unit. A study was performed comparing linear, conventional quadrature, and four-port excitation at 64 MHz and 200 MHz for different coil loadings, namely muscle phantoms and an anatomically detailed human head model. A phase array concept was utilized to excite the birdcage coil in four ports. Two phase conditions were analyzed, the simple fixed phase and the variable phase. At 200 MHz, compared to the conventional quadrature drive, the four-port drive reduces the effects of the tissue-coil interactions leading to more uniform. currents on the coil legs and consequently to a better B-1 field homogeneity. Also at 200 MHz, driving the coil in four ports provides an SAR distribution with peak values that are significantly less than those with linear or quadrature excitations. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:733 / 742
页数:10
相关论文
共 14 条
[1]  
Balanis C. A., 1989, ADV ENG ELECTROMAGNE
[2]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[3]  
BRIDGES JF, 1988, Patent No. 4751464
[4]   Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head [J].
Chen, J ;
Feng, ZM ;
Jin, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (05) :650-659
[5]   NUMERICAL-SIMULATION OF ANNULAR-PHASED ARRAYS OF DIPOLES FOR HYPERTHERMIA OF DEEP-SEATED TUMORS [J].
CHEN, JY ;
GANDHI, OP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (03) :209-216
[6]   SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil [J].
Collins, CM ;
Li, SZ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :847-856
[7]  
FIELD S, 1987, PHYSICS TECHNOLOGY H
[8]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[9]  
IBRAHIM TS, 1998, 6 ANN M INT SOC MAGN, V1, P652
[10]  
IBRAHIM TS, 1999, 7 ANN M INT SOC MAGN, V1, P2058