Liposome immunoassay using a spin label, TEMPO choline (4-[N,N-dimethyl-N-(2-hydroxyethyl)]ammonium-2,2,6,6-tetramethylpiperidine-1-oxyl): a new strategy for detecting this spin label using an ion-selective electrode in place of electron spin resonance (ESR)

被引:4
作者
Katsu, T [1 ]
Akagi, M [1 ]
机构
[1] Okayama Univ, Fac Pharmaceut Sci, Okayama 700, Japan
关键词
liposome immunoassay; ion-selective electrode; TEMPO choline; potentiometry; electron spin resonance;
D O I
10.1080/00032719808001833
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We devised a new method for detecting the spin label, TEMPO choline (4-[N,N-dimethyl-N-(2-hydroxyethyl)]ammonium-2,2,6,6-tetramethylpiperidine-1-oxyl), which is usually applied in liposome immunoassay, using a TEMPO choline-selective electrode instead of the conventional electron spin resonance (ESR) method. TEMPO choline was enclosed in the inner aqueous phase of liposomes, and the release of TEMPO choline from liposomes induced by the complement-mediated immune lysis reaction was monitored by this electrode. The potentiometric method using the TEMPO choline electrode was more effective for monitoring the immunoreaction and more economical than ESR method.
引用
收藏
页码:55 / 66
页数:12
相关论文
共 15 条
[1]   SPIN MEMBRANE IMMUNOASSAY - SIMPLICITY AND SPECIFICITY [J].
CHAN, SW ;
TAN, CT ;
HSIA, JC .
JOURNAL OF IMMUNOLOGICAL METHODS, 1978, 21 (1-2) :185-195
[2]   RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS [J].
COSOFRET, VV ;
BUCK, RP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) :1-58
[3]  
Guilbault G. G., 1979, ION SELECTIVE ELECTR, V1, P139
[4]  
Hsia J C, 1978, Ann N Y Acad Sci, V308, P139, DOI 10.1111/j.1749-6632.1978.tb22019.x
[5]  
HUMPHRIE.GK, 1974, P NATL ACAD SCI USA, V71, P1691, DOI 10.1073/pnas.71.5.1691
[6]   Potentiometric determination of alkaline phosphatase in blood serum using a hordenine-sensitive membrane electrode [J].
Katsu, T ;
Yamanaka, K ;
Hiramaki, S ;
Tanaka, T ;
Nagamatsu, T .
ELECTROANALYSIS, 1996, 8 (12) :1101-1104
[7]   AMINO-ACID-ANALYSIS USING AMINE-SENSITIVE MEMBRANE ELECTRODES [J].
KATSU, T ;
KAYAMOTO, T ;
FUJITA, Y .
ANALYTICA CHIMICA ACTA, 1990, 239 (01) :23-27
[8]  
Katsu T, 1996, JPN J TOX ENV HEALTH, V42, P453
[9]  
KORNBERG RD, 1971, BIOCHEMISTRY-US, V10, P1111
[10]   IMMUNE LYSIS OF SPIN LABEL LOADED LIPOSOMES INCORPORATING CARDIOLIPIN - NEW SENSITIVE METHOD FOR DETECTING ANTICARDIOLIPIN ANTIBODIES IN SYPHILIS SEROLOGY [J].
ROSENQVIST, E ;
VISTNES, AI .
JOURNAL OF IMMUNOLOGICAL METHODS, 1977, 15 (02) :147-155