AMON:: A wearable multiparameter medical monitoring and alert system

被引:353
作者
Anliker, U [1 ]
Ward, JA
Lukowicz, P
Tröster, G
Dolveck, F
Baer, M
Keita, F
Schenker, EB
Catarsi, F
Coluccini, L
Belardinelli, A
Shklarski, D
Alon, M
Hirt, E
Schmid, R
Vuskovic, M
机构
[1] ETH Zentrum, Swiss Fed Inst Technol, Wearable Lab, Elect Lab, CH-8092 Zurich, Switzerland
[2] SAMU 92, F-92380 Garches, France
[3] MDirect, IL-69377 Tel Aviv, Israel
[4] Aurelia Microelettron, I-55049 Viareggio, Italy
[5] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[6] Tadiran Spectralink, IL-11015 Kirayat Shmona, Israel
[7] Art Technol, CH-8048 Zurich, Switzerland
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2004年 / 8卷 / 04期
关键词
medical device; multiparameter; telemedicine; validation; wearable; wrist-worn;
D O I
10.1109/TITB.2004.837888
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper describes an advanced care and alert portable telemedical monitor (AMON), a wearable medical monitoring and alert system targeting high-risk cardiac/respiratory patients. The system includes continuous collection and evaluation of multiple vital signs, intelligent multiparameter medical emergency detection, and a cellular connection to a medical center. By integrating the whole system in an unobtrusive, wrist-worn enclosure and applying aggressive low-power design techniques, continuous long-term monitoring can be performed without interfering with the patients' everyday activities and without restricting their mobility. In the first two and a half years of this EU IST sponsored project, the AMON consortium has designed, implemented, and tested the described wrist-worn device, a communication link, and a comprehensive medical center software package. The performance of the system has been validated by a medical study with a set of 33 subjects. The paper describes the main concepts behind the AMON system and presents details of the individual subsystems and solutions as well as the results of the medical validation.
引用
收藏
页码:415 / 427
页数:13
相关论文
共 33 条
  • [21] Development of a new oscillometric blood pressure measurement system
    Moraes, JCTB
    Cerulli, M
    Ng, PS
    [J]. COMPUTERS IN CARDIOLOGY 1999, VOL 26, 1999, 26 : 467 - 470
  • [22] Nogawa M, 1998, P ANN INT IEEE EMBS, V20, P1858, DOI 10.1109/IEMBS.1998.746955
  • [23] A REAL-TIME QRS DETECTION ALGORITHM
    PAN, J
    TOMPKINS, WJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) : 230 - 236
  • [24] Pavlopoulos S, 1998, IEEE Trans Inf Technol Biomed, V2, P261, DOI 10.1109/4233.737581
  • [25] POUWELSE J, 2001, P 7 ANN INT C MOB CO, P251, DOI DOI 10.1145/381677.381701
  • [26] Mobile station emergency locating in GSM
    Silventoinen, MI
    Rantalainen, T
    [J]. 1996 IEEE INTERNATIONAL CONFERENCE ON PERSONAL WIRELESS COMMUNICATIONS, PROCEEDINGS & EXHIBITION - FUTURE ACCESS, 1996, : 232 - 238
  • [27] The challenges of wearable computing: Part 1
    Starner, T
    [J]. IEEE MICRO, 2001, 21 (04) : 44 - 52
  • [28] Tan KF, 2000, IEE CONF PUBL, P41, DOI 10.1049/cp:20000315
  • [29] TORAL SL, 2001, 2001 IEEE INT S CIRC, V4, P526
  • [30] A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement
    Ursino, M
    Cristalli, C
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (08) : 761 - 778