Thick membrane, solid contact ion selective electrode for the detection of lead at picomolar levels

被引:39
作者
Fouskaki, M [1 ]
Chaniotakis, NA [1 ]
机构
[1] Univ Crete, Analyt Chem Lab, GR-71409 Iraklion, Crete, Greece
关键词
D O I
10.1021/ac049013b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach for decreasing the lower detection limit of a lead ion selective electrode (ISE) is presented. The ISE is designed using nonfunctionalized porous glassy carbon loaded with ionophore/plasticizer/additive cocktail. This material acts both as the support for the liquid polymeric membrane and as the signal transducer of the ISE. The high purity of the glassy carbon, together with its high conductivity, allows for the development of a thick, low-resistance composite membrane. This sensor element enables the continuous measurement of lead down to picomolar levels, with very small detection limit deterioration due to the lead ion transport within the bulk of the thick membrane.
引用
收藏
页码:1780 / 1784
页数:5
相关论文
共 27 条
  • [1] INTRACELLULAR NEUTRAL CARRIER-BASED CA-2+ MICROELECTRODE WITH SUBNANOMOLAR DETECTION LIMIT
    AMMANN, D
    BUHRER, T
    SCHEFER, U
    MULLER, M
    SIMON, W
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1987, 409 (03): : 223 - 228
  • [2] LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS
    AMMANN, D
    PRETSCH, E
    SIMON, W
    LINDNER, E
    BEZEGH, A
    PUNGOR, E
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 119 - 129
  • [3] Theoretical and experimental studies of metallated phenanthroline derivatives as carriers for the optimization of the nitrate sensor
    Andredakis, GE
    Moschou, EA
    Matthaiou, K
    Froudakis, GE
    Chaniotakis, NA
    [J]. ANALYTICA CHIMICA ACTA, 2001, 439 (02) : 273 - 280
  • [4] Antropov L.I., 1972, THEORETICAL ELECTROC
  • [5] Ion sensors: current limits and new trends
    Bakker, E
    Diamond, D
    Lewenstam, A
    Pretsch, E
    [J]. ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) : 11 - 18
  • [6] DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES
    BAKKER, E
    WILLER, M
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 265 - 271
  • [7] BAKKER E, 2002, ANAL CHEM, pA402
  • [8] Buck R.P., 1994, PURE APPL CHEM, V66, P2528
  • [9] Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    Buhlmann, P
    Pretsch, E
    Bakker, E
    [J]. CHEMICAL REVIEWS, 1998, 98 (04) : 1593 - 1687
  • [10] Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes
    Ceresa, A
    Sokalski, T
    Pretsch, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 501 (1-2): : 70 - 76