The management of periprosthetic femoral fractures around hip replacements

被引:128
作者
Tsiridis, E
Haddad, FS
Gie, GA
机构
[1] Royal Devon & Exeter Hosp, Dept Trauma & Orthopaed, Princess Elizabeth Orthopaed Ctr, Exeter EX2 5DW, Devon, England
[2] UCL Hosp, London, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2003年 / 34卷 / 02期
关键词
LONGITUDINAL CRACK-PROPAGATION; INTRAOPERATIVE FEMUR FRACTURES; MENNEN PLATE FIXATION; CLAMP-ON PLATE; SHAFT FRACTURES; IPSILATERAL FEMUR; STRUT ALLOGRAFTS; PROXIMAL FEMUR; BONE STOCK; ARTHROPLASTY;
D O I
10.1016/S0020-1383(02)00257-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Periprosthetic femoral fractures are increasing in frequency and in complexity. They occur intra-operatively, or post-operatively, when they are frequently associated with loosening, with or without osteolysis. Periprosthetic femoral fractures usually occur at low energy levels, either after falls or spontaneously during activities of daily living. At present, the Vancouver classification system probably comes closest to the ideal, as it considers the fracture configuration, the stability of the implant and the quality of the bone stock. When the stem is stable, open reduction and internal fixation is suggested. Several authors have used strut grafts for the treatment of periprosthetic femoral fractures, with good results. If the stem is loose, or revision is indicated for other reasons, it is generally advisable to by-pass the most distal fracture line with a longer stem prosthesis by at least two femoral diameters. Augmentation of this intra-medullary fixation with an external cortical strut to improve rotational stability and/or internally with impaction allografting to compensate for bone defects is also advisable. Vigilant post-operative clinical and radiological assessment following total hip replacement should identify those with recurrent dislocation, loosening, subsidence and osteolysis. These patients are at greatest risk of developing femoral periprosthetic fractures. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 106 条
[11]  
CHRISTENSEN CM, 1989, CLIN ORTHOP RELAT R, V248, P177
[12]   FRACTURES OF THE FEMUR IN RELATION TO CEMENTED HIP PROSTHESES [J].
COOKE, PH ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :386-389
[13]   RE-ATTACHMENT OF THE GREATER TROCHANTER - THE USE OF THE TROCHANTER CABLE-GRIP SYSTEM [J].
DALL, DM ;
MILES, AW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (01) :55-59
[14]  
DALL DM, 1991, TECH ORTHOP, V6, P7
[15]  
Dave D J, 1995, J Arthroplasty, V10, P113, DOI 10.1016/S0883-5403(06)80075-6
[16]   Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528
[17]   PREVENTION OF LONGITUDINAL CRACK-PROPAGATION AROUND A FEMORAL PROSTHESIS - A STUDY OF CERCLAGE WIRE FIXATION [J].
DIFAZIO, FA ;
INCAVO, SJ ;
HOWE, JD .
CLINICAL BIOMECHANICS, 1993, 8 (05) :274-276
[18]  
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293
[19]   TOTAL HIP RECONSTRUCTION IN CHRONICALLY DISLOCATED HIPS [J].
DUNN, HK ;
HESS, WE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (06) :838-845
[20]  
Dysart S H, 1989, J Arthroplasty, V4, P187, DOI 10.1016/S0883-5403(89)80074-9