Chest wall irradiation with MLC-shaped photon and electron fields

被引:15
作者
Essers, M
Eggen, M
Binnekamp, D
Creutzberg, CL
Heijmen, BJM
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Div Clin Phys, NL-3075 EA Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, NL-3075 EA Rotterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 04期
关键词
MLC; electron beams; photon beams; chest wall; in vivo dosimetry;
D O I
10.1016/S0360-3016(00)00722-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To improve the treatment technique for chest wall irradiation, using the multileaf collimator (MLC) of the MM50 Racetrack Microtron to shape both photon and electron beams, and to check the dose delivery in the match-line region of these fields for the routine and improved technique. Methods and Materials: Using diode and film phantom measurements, the optimal number of photon beam segments and their positions relative to the electron beam were determined. On phantoms, and during actual patient treatment using in vivo dosimetry, the dose homogeneity in the match-line region was determined for both the routine and improved techniques. Results: Three photon beam segments (9-mm gap, perfect match, and 9-mm overlap) were used to match the electron beam, resulting in minimum-maximum dose values in the match-line region of 88-109%, compared to 80-115% for the routine technique (2 photon beam segments). During patient treatment, the average minimum and maximum dose values were 95% and 115%, respectively, compared to 78% and 127%, respectively, for the routine technique. The interfraction variation in dose delivery was reduced from 11.0% (1 SD) to 4.6% (1 SD). The actual treatment time was reduced from 10 to 4.5 min. Conclusion: Using the MLC of the MM50 to shape both photon and electron beams, an improved treatment technique for chest wall irradiation was developed, which is less labor intensive, faster, and yields a more homogeneous, and better reproducible dose delivery. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1205 / 1217
页数:13
相关论文
共 35 条
[1]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[2]  
Burns J E, 1996, BJR Suppl, V25, P153
[3]   Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry [J].
de Boer, JCJ ;
Heijmen, BJM ;
Pasma, KL ;
Visser, AG .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01) :197-216
[4]  
DEBOER JCJ, UNPUB INT J RAD ONCO
[5]   Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles [J].
Dirkx, MLP ;
Heijmen, BJM ;
van Santvoort, JPC .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1171-1184
[6]   In vivo dosimetry during external photon beam radiotherapy [J].
Essers, M ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (02) :245-259
[7]   Electron arc irradiation of the postmastectomy chest wall: Clinical results [J].
Gaffney, DK ;
Prows, J ;
Leavitt, DD ;
Egger, MJ ;
Morgan, JG ;
Stewart, JR .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (01) :17-24
[8]   Consensus statement on postmastectomy radiation therapy [J].
Harris, JR ;
Halpin-Murphy, P ;
McNeese, M ;
Mendenhall, NP ;
Morrow, M ;
Robert, NJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :989-990
[9]   IN-VIVO DETERMINATION OF THE ACCURACY OF FIELD MATCHING IN BREAST-CANCER IRRADIATION USING AN ELECTRONIC PORTAL IMAGING DEVICE [J].
HOLMBERG, O ;
HUIZENGA, H ;
IDZES, MHM ;
LEBESQUE, JV ;
VIJLBRIEF, RE ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1994, 33 (02) :157-166
[10]   Effect of set-up uncertainties on the dose distribution in the match region of supraclavicular and tangential breast fields [J].
Idzes, MHM ;
Holmberg, O ;
Mijnheer, BJ ;
Huizenga, K .
RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) :91-98