Chest wall irradiation with MLC-shaped photon and electron fields

被引:15
作者
Essers, M
Eggen, M
Binnekamp, D
Creutzberg, CL
Heijmen, BJM
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Div Clin Phys, NL-3075 EA Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, NL-3075 EA Rotterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 04期
关键词
MLC; electron beams; photon beams; chest wall; in vivo dosimetry;
D O I
10.1016/S0360-3016(00)00722-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To improve the treatment technique for chest wall irradiation, using the multileaf collimator (MLC) of the MM50 Racetrack Microtron to shape both photon and electron beams, and to check the dose delivery in the match-line region of these fields for the routine and improved technique. Methods and Materials: Using diode and film phantom measurements, the optimal number of photon beam segments and their positions relative to the electron beam were determined. On phantoms, and during actual patient treatment using in vivo dosimetry, the dose homogeneity in the match-line region was determined for both the routine and improved techniques. Results: Three photon beam segments (9-mm gap, perfect match, and 9-mm overlap) were used to match the electron beam, resulting in minimum-maximum dose values in the match-line region of 88-109%, compared to 80-115% for the routine technique (2 photon beam segments). During patient treatment, the average minimum and maximum dose values were 95% and 115%, respectively, compared to 78% and 127%, respectively, for the routine technique. The interfraction variation in dose delivery was reduced from 11.0% (1 SD) to 4.6% (1 SD). The actual treatment time was reduced from 10 to 4.5 min. Conclusion: Using the MLC of the MM50 to shape both photon and electron beams, an improved treatment technique for chest wall irradiation was developed, which is less labor intensive, faster, and yields a more homogeneous, and better reproducible dose delivery. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1205 / 1217
页数:13
相关论文
共 35 条
[11]   Radiotherapy of breast cancer after breast-conserving surgery:: an improved technique using mixed electron-photon beams with a multileaf collimator [J].
Jansson, T ;
Lindman, H ;
Nygård, K ;
Dahlgren, CV ;
Montelius, A ;
Öberg-Kreuger, C ;
Asplund, S ;
Bergh, J .
RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) :83-89
[12]   DOSIMETRIC EFFECTS OF ABUTTING EXTENDED SOURCE TO SURFACE DISTANCE ELECTRON FIELDS WITH PHOTON FIELDS IN THE TREATMENT OF HEAD AND NECK CANCERS [J].
JOHNSON, JM ;
KHAN, FM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :741-747
[13]   ELECTRON-BEAM CHARACTERISTICS OF THE 50-MEV RACETRACK MICROTRON [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1992, 19 (02) :307-315
[14]   MATCHING OF ELECTRON AND PHOTON BEAMS WITH A MULTI-LEAF COLLIMATOR [J].
KARLSSON, M ;
ZACKRISSON, B .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :317-326
[15]   Intensity modulation with electrons: calculations, measurements and clinical applications [J].
Karlsson, MG ;
Karlsson, M ;
Zackrisson, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1159-1169
[16]   Feasibility study of multileaf collimated electrons with a scattering foil based accelerator [J].
Klein, EE ;
Li, ZF ;
Low, DA .
RADIOTHERAPY AND ONCOLOGY, 1996, 41 (02) :189-196
[17]   ELECTRON ARC THERAPY - PHYSICAL MEASUREMENT AND TREATMENT PLANNING TECHNIQUES [J].
LEAVITT, DD ;
PEACOCK, LM ;
GIBBS, FA ;
STEWART, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (05) :987-999
[18]  
Marijnissen J.P.A., 1988, P S THERM DOS, P25
[19]  
MARIJNISSEN JPA, 1988, P S THERM DOS, P129
[20]   BEAM CHARACTERISTICS OF A NEW-GENERATION 50 MEV RACETRACK MICROTRON [J].
MASTERSON, ME ;
CHUI, CS ;
FEBO, R ;
HUNG, JD ;
FUKS, Z ;
MOHAN, R ;
LING, CC ;
KUTCHER, GJ ;
BJORK, S ;
ENSTROM, J .
MEDICAL PHYSICS, 1995, 22 (06) :781-792